Featured Post

Beolover SyncDrive: DC Platter Motor Replacement for Beogram 4002 and 4004 (Type 551x and 552x)

Late Beogram 4002 and the 4004 (Types 551x and 552x), which have DC platter motors instead of the earlier synchronous AC motors usually suff...

Wednesday, December 2, 2015

Beogram 8000: Replacing the Carriage Belt

Another loose end in the Beogram 8000 that I am readying for shipping I needed to attend to: I earlier noticed that the carriage belt was quite loose, i.e. at the end of its lifetime. On the occasion of my recent effort to replace a cracked BUNA-N volume belt in a Beomaster 6000 I ordered samples of the entire lineup of EPDM 1/16 O-rings at the O-Ring Store with the goal to be ready for future belt replacements of yet unknown diameters. So I thought I probably had the proper EPDM ring for the Beogram 8000 already in stock! And indeed: It turned out that the E70025 (1-3/16" diameter) ring made a good replacement of the original belt. Here are a couple of impressions:

This shows the original belt with rotary encoder sensor cluster removed (just pull the plastic clamp out and carefully pull the board up while making sure that the IR emitter passes through a gap in the encoder wheel), which is necessary to get the belts over the encoder wheel:

And here after installing the new belt:

It is interesting to note that my first attempt with a 1-1/16" belt did not work out. When I checked initially the carriage would move very well with it. However after attempting to play a record, it turned out that the Beogram would have trouble to move the arm to the run-in groove.

What happened was that the firmware in the microcontroller reduces the power on the carriage motor before the touch-down point to get a more precise positioning (and probably also because it just looks more elegant...;-). However this is apparently not done via encoder feedback but rather via a blind  flight power reduction without monitoring the encoder action. This resulted in a very slow movement of the arm do to the unexpected friction caused by the too-tight belt. It would take several seconds from moving swiftly near the position and then via a very slow final movement to the touch-down position. Replacing the ring with the 1-3/16 version cured this issue and now it behaves like with the original ring. All good now under the hood! Playing right now my just arrived 180g reissue of Queen's 'A Day at the Races' - those were the days!...;-)


Beogram 4002 (5521): Rebuilding the DC Motor

I started working on the Beogram 4002 that recently arrived. When doing my initial assessment, I noticed that the DC motor has completely dry sleeve bearings and so every time it would turn on without the belt and platter installed, it would emit a shrill noise due to the high RPM without a load. So this had to be fixed first. There must be peace and quiet in the Beolover's lair (and some nice vinyl playing while I do my work...;-). Here are a few pictures taken during the process. this shows the motor in-situ:

After removing the mounting plate, unscrewing the two screws that hold the motor to it and removing the glued on pulley (this may require some carefully administered force with a large screw driver to pry it off), I opened up the outer enclosure and extracted the motor:

Then I opened the motor up by removing the bottom shell that contains the brushes and the feedback coils:

Nice classic design! Then I extracted the rotor after removing all glue remnants on the shaft (this is important since otherwise the shaft gets stuck in the upper sleeve bearing and then damage can ensue:

Once at this point, all that is needed is to clean the commutator and the brushes with a fiberglass pen, lubricate both bearings with some silicone grease and then put everything back together in reverse. Note that it is crucial to make sure that both brushes are fully inserted onto the commutator before closing the motor back up. The pulley needs to be glued back on, too. Super Glue Gel works nicely. 

I did all that and installed the motor, and now it spins very quietly. Time to enjoy some vinyl! (just ordered an original 70s pressing of Miles Davis' "E.S.P", one of my favorite jazz records of all time)! - let's see if my vinyl record cleaner can salvage it...I really started liking using it...;-)




Beogram 8000: Installation of New Rubber Bumpers on the Hood and Beneath the Aluminum Lid

I still have a few odds and ends to clear up on the Beogram 8000 that I recently restored. While it is now playing nicely and all functions are restored, the hood was still missing its rubber bumpers and so did the aluminum lid. These rubber parts decay over time and then they break off. But they are important to give the user the correct feel and sound when letting the hood or the lid close on their own. I have not seen a 8000 that still has all of them. Luckily, my own 8000 still had an original one, so I was able to take some measurements. Since these bumpers are not available anywhere, I resorted to using a 1/16" rubber sheet and double sided tape to repair the one under the aluminum lid. The bumpers on the hood cannot be fixed that way, but a piece of .1" O-ring does the job...see below.

Here is a picture of the small cavity that holds the bumper under the lid: 

This shows the hole punched pieces with the double sided tape on them:

I found that a 3/16 punch generates perfectly fitting bumpers:

Pretty! On to the hood. This shows the missing bumpers on the right side:

And with the 0.1" O-ring section forced in but still too long:

To get the precise 1mm height of the bumper, I 3D printed myself a mask for cutting the rubber segments off in parallel to the hood edge with a razor blade:

This picture shows the fit of the hood after cutting the rubber segments off:

Perfect alignment with the control cluster. This is Beolove!





Monday, November 30, 2015

Beogram 4000: Installation of a New Gold Coated DIN5 Plug and a Grounding Switch

The beautification of the Beogram 4000 that I am restoring right now continues. I installed a grounding switch and a new gold plated Neutrik DIN5 plug. The grounding switch allows to combine signal and system grounds of the Beogram. This essentially allows to switch between the grounding scheme of the later 4004 models and the 4000/4002 set-up where system and signal ground are separated. Depending on the amplifier set-up it can be beneficial to be able to select either one to avoid the formation of ground loops that can cause humming. I recently made a post that illuminates this in more detail.

This shows the switch installed. The shown orientation corresponds to the original 4000 set-up with separated grounds. Flipping it to the left would connect both grounds:


Here are a few pictures of the DIN5 replacement. This shows the corroded original plug:


And here is a picture of the new plug:

Beautiful! this shows the leads as connected on the inside:

Good to know that the precious MMC signals can now travel unimpeded!


Sunday, November 29, 2015

Beogram 4002 (5521): A New Arrival - First Impressions

A Beogram 4002 (5521) model in nice cosmetic condition arrived a couple of days ago for some TLC. The unit came with an indication of dead tracking sensor and 33 RPM light bulbs. It also came double boxed, which helped ensure uneventful travels (I recently made a video describing preparation for shipment and packing of a 4002/4. It is posted here). This shows the inner box:

and after taking the unit out: The foam pads held the sub platter down. Very important are the strips of no-residue tape holding the arms and the RPM panel in place during shipment.

The condition of this 4002 is very good except a few minor blemishes like a small shaved off bit of veneer on the right corner of the plinth:
The keypad is also in pretty good condition showing only minor finger marks on the coating:

The hood has the usual scratches commensurate with nearly 40 years of service:

Remarkable is that the Beogram 4002 lettering is missing on the aluminum trim in the back of the hood:

Finally there are a few marks on the arm weight cover, which hopefully can be removed:

Operationally, I noted that in addition to the dead light bulbs the motor urgently needs lubrication. It is emitting shrill noises when running without platter installed, a clear indication of dry sleeve bearings. Furthermore, the transport locks are disintegrating as is evident from the telltale orange plastic fragments distributed throughout the unit:

Unfortunately, the MMC20EN cartridge that came along has a suspension problem. The cantilever is at an off angle. It is interesting to note that the last 4002 that I restored also had an EN cartridge with exactly the same issue. I hope this is not a pattern...Here are a couple pictures:


This can be fixed by Schallplattennadeln.de or Soundsmith. Waiting for a reasonable offering on ebay is another option. In summary, however, I would say this 4002 is a pretty good starting point for a restoration.








Saturday, November 28, 2015

Vinyl Record Cleaner: Design Iteration 2

I cleaned a few records with my initial design of a vinyl record cleaner that uses Mr. Clean Magic Eraser pads. It seems to be very effective. Many previously crackly records sound now like new. Absolutely Magic!

But I was not satisfied with the handling of my initial design, and so I made a few changes. I beefed up the wall thickness by 0.5 mm and also introduced a longer pin that holds the record. That makes it much more straight forward to insert a record since one does not have to press it down anymore onto the lower pad to be able to get the pin through the center hole. Furthermore, a plateau was added at the outer end of the contraption that sits flush with the top part when both parts are put together. This took all instability and 'wiggle' out of it when pressed on a surface for the cleaning action. Here are a few pictures. The two parts with cut to size pads:

In action:

This shows the dirt that was taken out of the grooves of a 12" single of Foreigner's "Urgent" (one of my youth favorites...;-) that I recently bought via Discogs in "Near Mint" condition and that proved a big crackly disappointment:

Now it is running very quiet and could indeed be called 'Near Mint'. Mr. Clean rocks!



Beogram 4000: Adjusting the Chassis Springs and the Platter Height

The Beogram 4000 that I am rebuilding right now is entering the 'beautification phase'. It works now very well, and what is left are the exterior and a new good plated plug etc...So I set out to adjust the platter height and tilt and the leaf springs that hold the floating chassis of the turntable. This task is a relatively complex one since one has to "try[] to hit a bullet with a smaller bullet whilst wearing a blindfold, riding a horse" (to say it with Scotty in the 2009 Star Trek reboot...;-). Since sensor arm orientation relative to the floating chassis, platter tilt angle relative to the chassis, linear travel in the opened transport lock and belt tension all play significant roles in the adjustment process, one needs some patience and may have to redo things a few times until one hits the sweet spot where the platter is centered and leveled with the aluminum panels and parallel to the arms, and the chassis does not touch the locks when they are open.

I recently made a couple of videos that show the basic approach. They are posted here. Here are a few pictures of the fully adjusted platter relative to the aluminum panels:

And an 'in-action' detail. She is getting real pretty now!..;-): 

The aluminum panels were quite dirty on this unit. Here is an area in comparison before and after cleaning with Mr. Clean Magic Eraser pads and some (hand-) dishwashing detergent:
Before:

And after:

What would we do without Mr. Clean??!!