Beolover SyncDrive: DC Platter Motor Replacement for Beogram 4002 and 4004 (Type 551x and 552x)

Late Beogram 4002 and the 4004 (Types 551x and 552x), which have DC platter motors instead of the earlier synchronous AC motors usually suff...

Thursday, November 19, 2026

Beogram 4004: Restoration of the DC Platter Motor

A DC platter motor from a Beogram 4004 recently arrived from a customer in California for an oil infusion of the shaft bearings. Here is the motor as it arrived:


I took it apart to extract the bearings:


The bearings are the two small donuts on the black pad in front. I submerged them in synthetic oil and drew a vacuum. Bubbling began right away:


The bubbles are air escaping from the porous Oilite bearing material. As air exits the pores, oil is able to diffuse into the material. This infusion can take up to three days. Once the bubbling ceased, I removed the bearings from the vacuum chamber:


Next, I put the motor back together and mounted it in my test bench Beogram 4002 for a 24 hrs RPM stability run using my BeoloverRPM unit:


In its 'slow' mode, the BeoloverRPM can record RPM readings at 10s intervals via a serial port on any PC. Here is the curve recorded after roughly 24 hrs:


This plot is about as solid as it gets for restored Beogram DC platter motors. There is only minimal long-term drift due to ambient temperature changes over 24 hrs. This motor is ready for another tour of duty!