Beolover SyncDrive: DC Platter Motor Replacement for Beogram 4002 and 4004 (Type 551x and 552x)

Late Beogram 4002 and the 4004 (Types 551x and 552x), which have DC platter motors instead of the earlier synchronous AC motors usually suff...

Monday, October 10, 2016

Beogram 4002 (5501): Sensor Arm Light Bulb Replacement - Final Version

This is a follow up to my recent post about the replacement of incandescent sensor arm bulbs in Beogram 4002 turntables with a LED setup. Subsequent experiments revealed that the best position for the LED PCB is when it is pushed down by about 2.5 mm into the bulb cavity of the sensor compartment. This position yields the highest sensor response as measured at the collector of 1TR8 (5501; pre SSN 257556 notation), and I think this makes sense since the light bulbs have the filament always a bit lower than the upper rim due to the glass bulb.
I like reproducible solutions, and so I designed a small 3D printed wedge that can be epoxied on the outside of the flexPCB and that presses the LED down by the correct amount when the bulb compartment is closed:
This shows the LED powered up at 5.5V:
The board has a ballast resistor that adjusts the current draw to the prescribed ~60mA. This is necessary that the 'bulb malfunction detection circuit' is not triggered on the main PCB of the Beogram.

This shows the board installed and lit up:
This shows the TR8 signal:
Note how nicely the curves bottom out at 0V.

This shows the setup 'in action':
Note the nice red-orange glow of the B&O logo. This is a result of using a 2600K color temperature high intensity white light LED that has a considerable amount of red light in its emission spectrum which enables a 95% color rendering index (CRI). Also the light spot is nice and tight indicating that the light source is in the focal point of the exit collimator.
This pretty much concludes the development of the LED implant for the Beogram 400x sensor arm. Henceforth Beolover restorations can (if so desired by my customers) yield Beograms devoid of incandescent bulbs.





Friday, October 7, 2016

Beomaster 8000: Rattling Main Relays and a Broken 2MHz Oscillator Crystal

*********************************************************************************
ACHTUNG: Please, note that the crystal exchange procedure described here can damage the microprocessor chips on the uProcessor board. It is recommended to remove the chips before replacing the crystals and the capacitors. Due to the inherent capacitance of these devices, high voltages can be present between their terminals, which upon release, can burn out the gate that forms the oscillator together with the crystal. Make sure you short circuit the leads of the parts before installing them.
*********************************************************************************


Oh well, nothing lasts for ever!...The fully restored (2011) Beomaster 8000 that I am using in our living room recently broke with a rather strange fault. I woke up at 4 am in the morning to the beeping of an uninterruptible power supply (UPS) in distress. First I thought we had a power outage, but it turned out that the UPS turned itself off due to a malfunction in the connected Beomaster 8000 (I run all my B&O equipment on UPSs to reduce the risk of damage from grid voltage spikes and the like). I restarted the UPS and immediately the main transformer power relays of the 8000 started going on/off in rapid sequence. And then the UPS caved in again, turned itself off and started beeping again. This immediately pointed to a severe fault in the 8000 since a UPS only shuts down if the current drawn exceeds the rated 10 or 16 amps. This suggested to not try running the Beomaster again before having a look inside.

I shut everything down and went back to bed. The next morning I swapped the 8000 out with one of the other 8000s I have around the house in less important locations. A few days later I opened the malfunctioning unit up and ran it. First everything was normal but after a while it started to rattle again. I switched it off immediately and started wondering what might cause such behavior. First I thought there is a problem in one of the outputs triggering the protection circuit. The reason was that I initially detected 15V at the output of the protection circuit (collector of 6TR15) during relay rattling phases. The 15V pull up the base of 6TR11 via 6D12, which then causes the relays to go off, cutting power to the main transformer. This is usually caused by malfunctioning output transistors or overheating of the outputs. However, in this case the 15V were rather a consequence of an entirely different root cause.

After some playing around with the unit and enjoying a few more UPS shutdowns and relay rattling events, I finally figured out that the crystal oscillator of 9IC4 on the main processor board had some issues. I figured this out due to two phenomena:

1) After one of the rattling episodes I was not able to turn the Beomaster back on. The standby LED was lit, but no more reaction to the keypad. Panic ensued since I thought I had accidentally fried the processor or some other disastrous event occurred. So I did a processor self-test by pressing the Monitor key first and then additionally the on/off bar on the keypad. This initiates a self-test sequence. And I finally saw my first error code on a 8000: TE8!
The manual yields a rather cryptic cause for this error:

"Error TE8:    Defect IC:9IC4(RAM)      Or short pin to chassis: 10-11"

Initially I thought I had really fried the slave processor that is responsible for the relays...but then ,after my initial panic subsided and normal brain functions kicked back in, I thought that my maxim "silicon usually dies last" should apply here too, since even a complete main power supply failure and dramatic short circuit etc...would have a hard time killing anything on the processor board. There is simply no direct connection. Furthermore, when I tried to turn the unit on again after an hour or so, it worked normally again indicating a healthy state of affairs on the processor end of things (silicon either is alive or dead...rarely there is an intermittent state in my experience). Also, once it worked again, the error code went away and I got this from the self-test:
A happy Test Passed (TP).

2) The second indication toward the oscillator issue came from an oscilloscope measurement I made after the error code episode:
The probe was hooked up to the base of 6TR11, which is connected to Pin 16 of 9IC4 via some resistors. At this point the unit was working and there was no rattling from the relays at all. But you see some type of digital random oscillation of the signal that normally should be just near-0V when the unit is on. The digital character of the signal already suggested to me that there might be a processor issue...I watched this for some time and then it changed to a more aggressive behavior:
A much stronger deviation from 0V and still pretty random and close to switching 6TR11! And then it went completely crazy and the relay clicking started again as 6TR11 did its job. I did not save the measurement at that point since I was busy turning off the unit as fast as I could...;-). This finally put me on the right track, however, and I started looking into 9IC4. The same random signals were also directly visible at Pin 16 of 9IC4, just on a 0-5V scale since at Pin 16 we are directly at the source of the signal and there are no resistors over which the voltage drops. This told me that indeed the processor was going 'crazy' occasionally. This combined with the error information above that alternatively to a processor malfunction also Pins 10-11 could be 'grounded' finally made me see the light since the oscillator crystal is connected to Pins 10 and 11!

I wiggled the crystal a bit and indeed, I was able to cause the Pin 16 signal to change from completely quiet 0V to the above shown random signals and to 'crazy' causing relay rattling. So I guess what happened was that the clock of the processor started to have random hiccups causing timing issues while processing its firmware, which then caused the normally constant output at Pin 16 to become random triggering the relay circuitry.

I ordered a few 2MHz crystals from Newark (21M6819) along with matching 18pF resonator capacitors (46P6436) - the original crystals run on 12 pF capacitors, i.e. they need to be exchanged along with the crystal to get a proper oscillator signal. After a few days I received the parts and put them in. This shows the original crystal with the two capacitors (brown, right below):

This shows the board with the parts removed:
This is the new smaller crystal in comparison to the original one:
Like most components modern ones are considerably smaller than the original ones...and this finally shows the new units implanted (I also exchanged the 9IC3 components assuming both the original crystals were from the same batch...;-):
The exchange is straight forward, but the right capacitors are difficult to remove since one of their legs is fed through a hollow via, which is a bit of a pain to unsolder due to the very small space between lead and via insert. One has to hold the solder tip to the via to liquefy the solder and then pull the cap out...three hands would be great for this process...;-)

One more thing: It is crucial to cut the leads on the solder side of the board very short to prevent short circuits to the EMI can that encloses the processors:
I had them too long initially, and I got some really spectacular readings on the displays when I turned the unit on. Essentially, it became completely unresponsive showing some random zeros on all of the displays. Another near-heart attack...;-). Cutting the leads solved that problem...live and learn...;-) 
I am running the unit now for a couple days back in the living room and it seems the issue has gone away. Also wiggling the crystal did not cause the issue anymore. So I am assuming we are back in business with this lovely Beomaster 8000!

Remarkably, a few days after this happened to my 8000 I received an email from an Australian customer whose 8000 I restored a couple years ago telling me that his Beomaster developed the exact same symptoms (I am sending him a couple crystals and the capacitors plus some instructions...this is Beolove!).
So I am thinking that exchanging the crystals should become a standard part of any Beomaster 8000 restoration...two at the same time is a rather strange coincidence, which points to a systematic issue with these crystals. Probably the leads are delaminating from the crystal material after 30-35 years...
Time to get back to my other restoration projects!











Thursday, October 6, 2016

Beogram 4002 (5501): Replacing the Sensor Arm Bulb with a SMD LED on a FlexPCB

***************************Sequel to this post see here******************************

I finally was able to design a LED based upgrade to replace the sensor arm incandescent light bulb in Beogram 4002 units. This was the most difficult bulb to replace due to the tight space available in the sensor arm and the requirement to put out an incandescent looking light spot, while being able to properly back-illuminate the lovely orange-red B&O logo at the end of the arm. 
I quickly realized that only a flexPCB would be able to do the trick. My first experiments involved high brightness amber LEDs combined with a red LED to provide some longer wavelength photons to give the B&O logo a more red appearance. Here is an impression of the design:
While this worked technically, the light spot on the record was way too orange, while the red LED could not compete with the amber unit:
Worse, the red LED could be seen reflected in the record surface separated from the amber spot due to the different projection of the red LED through the lens that focuses the light on the record surface. Anyway, this was not Beolovely, and so I did some research and finally found a latest-development warm white LED with a 95% color rendering index (CRI) value, which promised that this LED would be able to correctly illuminate the B&O logo while looking fairly natural when reflected from the record. This is how my board looked like with it on there:
And fired up:
It is a pretty warm white (2600K temperature equivalent). And this shows the board folded into the sensor arm cavity:
And in action:
Pretty authentic look, even though of course the light spot is not a projection of a bulb filament, i.e. it is a bit more homogeneous than the original bulb pattern. But I think without pointing this out to someone, it would be hard to tell that a white LED is at work here. So far so good...but the real test is of course whether this setup can make enough signal at the sensor output for a reliable detection of the absence of a record. For this I measured the sensor signal on the platter without a record present. This is the signal after being amplified by TR8:
Note that the dips go all the way to zero, which is what is required to properly disable arm lowering when there is no record. Bulbs rarely deliver a stronger signal, so this seems adequate!
Another critical factor is the current draw of the LED board. The Beogram 4002 is equipped with a detection circuit that disables arm lowering if the bulb filament breaks. This circuit requires about 50-60mA in the bulb circuit to enable arm lowering. So I added a resistor to the LED board to match 60mA (the LED on its own only draws about 40 mA...). This shows my bench power supply driving the board with 5.5V (same voltage as is applied to the bulb in the sensor arm):
It appears we have a functioning prototype in play! All that needs to be done now is to clean the board design up a bit to arrive at a final version. This is Beolove!








Monday, October 3, 2016

Beogram 4002 (5501): Installation of New Transport Lock Bushings and New Cabinet Guidance Washers

The restoration of the Beogram 4002 (5501) that is on my bench right now is coming slowly to a conclusion. After restoring the worn keypad surfaces, I moved on to the transport locks and the cabinet guidance washers. The transport lock bushings should always be rebuilt before the floating chassis is adjusted that it sits centered in the enclosure.

There is a video about installing new transport lock bushings in my Beogram 4002 playlist. The bushings can be ordered directly from my Shapeways store. This is the link to the part. You will need two per transport lock.
Here are a few impressions: The picture below shows the situation (as found in most Beogram 4002s with the orange bushings). The bushings are completely fragmented and I had to remove the fragments with a vacuum from throughout the enclosure.

This shows one of the orifices in the sub chassis after cleaning up the fragments:
Installation of the new bushing is simple. They come in two parts which are installed from the top and bottom:
Then the lock can be reinstalled:
It is important to put the bolt in in its correct orientation (the longer end points down). This shows one of the locks fully done:
After that I replaced the cabinet guiding washers. The older 4002s all came with plastic washers, which are often cracked. The 5501 even has the same strange front-center washer like the 4000:
I always replace these with my reproduction parts since they do not guide the cabinet, just hold it down. This particular washer is best replaced with a black guiding washer. Otherwise it can be seen through the crack between cabinet and aluminum panel:
There is a video about this procedure in my Beogram 4002 playlist. The guidance washers can also be ordered directly from my Shapeways store. This is the direct link to the part. You can still use the (lower priced) white version, just use a Sharpie pen and 'paint' it black. The selective laser sintered (SSL) Nylon material is a bit porous, i.e. the ink nicely soaks into the bulk of the washer, giving it a durable black color.






Monday, September 26, 2016

Beogram 4002 (5501): Worn Keypad Restoration - My Process Finally Appears Reproducible...

The Beogram 4002 (5501) that I am restoring right now had the usual worn keypad. Here is an impression of how it looked before I restored it:
As usual the start button was worst...no surprise since it sees most of the action during normal play activities. This shows the keypad after my restoration procedure:

Nice! Looks almost like new!!...It took me a few months and many frustrating attempts to perfect my approach to rebuilding these keypads. But it seems my process finally yields a reproducible outcome. Another piece of the 4002 restoration puzzle in place! 

This keypad had one more issue: One of the RPM panel clamps was broken out preventing the RPM panel from staying down:
This shows the broken part in comparison with a good one that I had 'in stock':
I replaced it and now the keypad looks perfect. But I guess it is time to develop a 3D printed replica...Beolove never ends...;-)





Wednesday, September 21, 2016

Beogram 4002 (5501): Replacement of End Groove Detection Light Bulb with an LED

After restoring the RPM trimmer panel of the Beogram 4002 (5501) that I am rebuilding right now, it was time to look into the not working end groove detection mechanism. This mechanism is an exciting part of this design. It uses a light bulb and a photoresistor in conjunction with an encoder wheel doubling as pulley to detect the moment when the carriage starts moving faster after the last track of a record is over. This allows cutting short the time it takes until the arm returns to the home position on records that have a wide end groove section (such as many 12" singles or some short playtime LPs).

This shows the setup:
The bulb illuminates small holes that are in the pulley that is driven by the carriage motor. The light sensor is located on the other side of the spindle bearing. Unfortunately, the light bulb fixture of this Beogram had a broken off tab requiring some tape to hold it in place. Here is a picture of the bulb assembly pulled from the bearing unit:
The tab goes into the groove on top of the pulley bearing assembly. The back part of the tab is missing. You can also see very nicely the crack in the pulley. Nick is already working on a redesign of his standard aluminum pulley for the 4002 to add the small holes necessary for the end groove detection mechanism to work. Thanks Nick!

Naturally, this was not a Beolover acceptable state of affairs and so I designed a replacement part upgrading the system with an LED.

Here are a few impressions. This is the finalized component holding an amber high intensity LED (Newark 78R6602) and a 2k resistor (Newark 26R3983) reducing the current to below spec level of the LED. The resistor sits in a small holder on the left side to keep things neat and tidy:
This shows it illuminated at 23V:
And installed:
It press-fits right on top of the pulley bearing assembly
This shows it in action after the end groove circuit is activated via a carriage position switch:
I tested it and it seems to work great.

Here is an explanation how the end groove detection system works:
This shows the relevant section of the circuit diagram:
0IL1 is the LED. The switch 8009021 is the second carriage position switch on the B-rail:

Once 0IL1 comes on, the holes on the pulley begin to illuminate OR2. This causes voltage fluctuations across 1C35 which briefly turn off TR21. This applies a brief voltage pulse to C33 via D31 and R90. Hence, every time a hole of the pulley comes in between 0IL1 and OR2 a small amount of charge is put into C33. Therefore, over time the voltage on C33 increases proportionally to that charge. Once the voltage is high enough, TR20 turns on. TR20 is connected in parallel to the end switch ("ES", A), i.e. to the control system a TR20 in "ON" condition looks like ES was triggered and the arm lifts and the carriage returns home.

You may wonder, "what happens when the lamp turns on, but the needle is still on the last track of the record, and a pulley hole comes by and C33 charges up?" This is why D30 and R91 were added to the circuit as a (competing) path to discharge C33. R91 essentially determines the time it takes to discharge C33, and it was adjusted to discharge it fast enough to compensate for the charge build-up when the pulley only moves slowly when a track is played. In the end groove, however, the carriage moves much faster, and so the pulley holes come by more often, which overwhelms R91, and so the voltage can build up on C33, finally triggering the ES process.

If TR20 is not triggered due to a malfunction of the end groove detection system (dead bulb, for example), the arm will go all the way to the end of the end grove and then ES will be triggered by the carriage and save the day. All the end groove detection system does is to spare the user the wait until the arm goes all the way to the end (and to listen to the static from the groove). A typical B&O approach. Why not make it more perfect if you can?? This is Beolove!








Monday, September 19, 2016

Beogram 4002 (5501): Restoration of RPM Trimmer Panel

After rebuilding the PCBs of the Beogram 4002 (5501) that I am currently restoring, I turned my attention to the RPM trimmer panel. This panel had been replaced previously with the aim to repair a burned out trimmer scale illumination bulb. As a first step I re-worked the solder connections in the wires where the original panel had been cut off. This shows the situation when I received the deck:
I re-soldered all connections and installed proper diameter shrink tubing to protect the solder joints:
Then I replaced the bulbs with my LED replacement boards:
These are specially designed for the 550x Types since the bulbs partake in the RPM switching process, i.e. the LED circuits need to present a similar resistance/current draw as the original bulbs.
Like all my parts, these boards are available to other enthusiasts. Just send me an email, or use the contact form to the right. This video shows how to install the LED boards.

This shows the original situation (I already had removed one bulb when I remembered that I needed to take a picture...):
Then I installed the LED boards:
then I briefly confirmed that the LED replacements worked properly, and then I removed the white plastic fixture from the aluminum panel, since my customer wanted to use a different better-conditon panel instead of the one that was installed. This required to cut off the retaining rings on the aluminum posts after which I was able to remove the assembly:
What I found were already wavy white background strips that serve the back illumination of the ed RPM indicator hands. Wavy backgrounds cause inhomogeneous back illumination, i.e. they are better replaced if long term stability is desired. I usually replace them with white electrical tape:
After that I put the assembly on the new aluminum panel attaching it with M3 circlips and nylon washers. This shows the final outcome with the bulb covers installed over the LED panels:
And here an impression of the front side with 33 RPM selected:
Pretty! And it looks warmly incandescent (a result of using red and green LEDs to mimic the emission spectrum of incandescent light bulbs). All good again in the RPM panel department!