Featured Post

Beolover SyncDrive: DC Platter Motor Replacement for Beogram 4002 and 4004 (Type 551x and 552x)

Late Beogram 4002 and the 4004 (Types 551x and 552x), which have DC platter motors instead of the earlier synchronous AC motors usually suff...

Friday, January 20, 2017

Beogram 4000: Restoration of the Control Panel - LEDs and Gold Plating of Switch Terminals

After gold plating the carriage position switches, it was time to rebuild the control panel of the Beogram 4000 that I am restoring right now. I usually replace the incandescent light bulbs with LED assemblies, and I gold-plate the switch terminals to ensure trouble-free operation down the road.
This shows the original keypad switch terminals, which were quite oxidized:





















I removed the terminals:
And gold coated them after removing the oxidation with a fiber glass pen:
And like with the last Beogram 4000 that I did, I forgot to remove one terminal in my first approach...not funny! Here we go:
and after coating:
Pretty, aren't they?? Then I soldered them back into the PCB:
The next step was to replace the light bulbs with LEDs. This shows them in action:
The position scale illumination bulbs were replaced with my custom designed dual red/green LED assemblies:
These boards are available to other enthusiasts. Just send me an email if you want to upgrade your Beogram 4000!
The bulbs that illuminate the RPM trimmers from the back were replaced with through hole high brightness LEDs that are dimmed with 3.3k resistors:
Using strongly dimmed high brightness LEDs saves more current further reducing the strain on the transformer of the Beogram (which gets pretty warm during play) along with the other LEDs that I implanted.
This is an impression of the LEDs in action:
The red-green LEDs create a very authentic background illumination for the position indicator while the presence of red photons in the LED light ensures that the indicator shows up red like when illuminated with incandescent bulbs.

















Monday, January 16, 2017

Beogram 4000: Gold-Plating of the Carriage Position Switch Terminals

The next step of my Beogram 4000 restoration was to electroplate the carriage position switch terminals with gold. In my experience 90% of all operational trouble with this B&O design comes from oxidized switch terminals. These switches present the digital control system with the necessary inputs about the carriage status and if they malfunction, the control system gets thoroughly confused. So my recommendation is gold-plating of the switch terminals. Gold does not oxidize easily and therefore this will result in significant long-term reliability improvements. This shows the carriage switches as I found them:
Not too bad compared to what I found before in other Beogram 4000s, but definitely some black spots indicating oxidation. I removed the terminals:
The oxidized contact points are clearly visible. I cleaned and gold plated them:
And soldered them back into the circuit board:
the next step is to do the same for the switches in the keypad.




Sunday, January 15, 2017

Beogram 4000: Restoration of the PCBs - New Capacitors, RPM Trimmers and RPM Relay

After replacing the motor and reservoir capacitors of the Beogram 4000 that I am restoring right now, it was time to rebuild the PCBs. I usually replace all the electrolytic capacitors, the RPM trimmers as well as the RPM relay. This shows the main PCB 'flipped' out (the 4000 PCBs cannot be removed easily since they are hard wired to the other components):
This shows the rebuilt board after replacing the components:
The new relay in detail:
They are available to other enthusiasts. Just send me an email or use the contact form on the right. It is a good idea to replace them, since the original Siemens relays are often oxidized preventing proper RPM switch-over. On to the RPM trimmers:
I use 25-turn trimmers, which make it very straight forward to adjust the RPM precisely and durably. 1VR1 (33 RPM) is 50k and 1VR2 (45 RPM) is 10k. This shows how the adjustment screws protrude through the PCB that one can adjust the RPM with the board bolted in.
There are two more capacitors on the smaller power supply PCB. This shows it in its original condition:
And after replacing the two red tantalum caps:
On to the remaining restoration tasks.






Beocord 9000: Displays and Lamps

I left this Beocord 9000 project off waiting for some Beolover displays to arrive and preparing to give the beocord a quick functional check to see if it records and plays cassette tapes. I am happy to report the replacement lamps have arrived and my record/playback tests also worked. Once I finish the displays I will go through some organized cassette functional tests and show the results.

The display work can all be done with the Microcomputer and Display board in place inside the Beocord. Here are the display components looking from the top (so you can see the PPM scale lamp clearly).

















I shouldn't have to touch the PPM displays other than the PPM Scale Lamp. I will replace the scale lamp and the indicator lamps with the LED replacement modules I got from Beolover. The 7 segment display will be disassembled, the original LEDs will be removed and modern surface mount LEDs will be installed in their place. Here is another picture of the Beocord 9000 as one would normally view the Beocord.





















The first lamp to get replaced is the PPM Scale Lamp. Beolover originally posted the installation of one of these in the Summer of 2015. As mentioned on that thread, the Beolover tonearm position indicator LED replacement module can be re-purposed for the Beocord 9000 PPM scale lamp. Here is the part as I received it from Beolover.

















As shown on the 2015 Beolover thread, the replacement is very straight forward. I like drop in replacements. This sequence of pictures shows the replacement.





































This picture shows the Beolover replacement lamp modules for the four indicator lamps. There is also a 2015 Beolover thread on this subject.





















The above picture also shows the seven segment display has been removed. It is time to prepare that part for restoration. Here is what the seven segment display module looks like taken apart.

















This is a better shot of the seven segment display LED board (front and back).




































The smallest dots on the display are the original lamps. This picture shows that each lamp has a tiny wire strand on one end of the display lamp. That delicate wire can be broken or about to break.















I will continue this seven segement display module restoration in the next post.

Wednesday, January 11, 2017

Beogram 4002 (5513): A New Exciting DC Motor Failure Mode Due to a Shorted Spark Snubber

Another Beogram 4002 (5513) DC motor arrived recently for some TLC. When I did the usual pre-restoration test in one of my Beogram 4002s, this motor only ran very sluggishly and only if I would help it along a bit. This made it stand out from the usual DC motor that I am seeing on my bench. Usually, these motors run vigorously, but they have strong RPM variations and often make shrieking noises due to dry Oilite bearings. This one was very lackluster and weak in comparison.
I opened it up and did my usual oil infusion of the bearings to make sure that the mechanical aspects were up to spec before I would look into the sluggishness issue. Here are a few impressions of the Oilite bearing oil-re-infusion process. This shows the motor as received:

And disassembled:
This are the bearings in motor oil under vacuum:
The bubbles rising from the smaller (bottom) bearing is air being released from the porous Ni "Oilite" material while it is being replenished with oil. The top bearing only released a few bubbles indicating that it still had oil in it.
After 24 hrs the bubbling stopped and I reassembled the motor. When I tested it the sluggishness had not changed, i.e. there was definitely another issue beyond dry bearings.

I opened the motor up again and I remembered that I had a similar issue a while back. In that case I was able to get the motor running again after removing the spark snubbers that are connected across the three coils on the rotor. Spark snubbers short circuit the EMF that is generated due to Faraday's law when the commutator switches between coils. This prevents sparks and potential damage to the driver circuitry. This shows the rotor hooked up to a multimeter in resistance measuring mode:
The three blue units arranged on a ring around the commutator are the snubbers. Normally, they are insulating at the low voltages typically applied during a resistance measurement. The 16.8 Ohm that show up here is the resistance of the rotor coil this particular snubber is connected in parallel. I measured the snubber one over:
22.9 Ohm for the next coil. On to the third snubber:
This measurement shows that it has a short. This effectively takes the associated coil out of business and this explains why this motor did not have any power. It only ran on two cylinders instead of three, so to speak. From the previous motor with this issue I still had the three-spark-snubber assembly in my B&O parts box. This shows it in front of the rotor:
I cut out (they are spot welded together) the shorted snubber from the rotor and implanted one of the still working ones of the extracted assembly:
A test with the multimeter showed that this coil now had again about 20 Ohms.
I reassembled the motor for the second time, and inserted it into the Beogram 4002. I hooked up my BeoloverRPM device (which is available to other enthusiasts - just send me an email or use the contact form to the right) and did a 12 hrs run. This is the curve I measured:
It appears this motor is up to spec again.

I read up a bit about spark-snubbers in motors. There are many different types of these devices. A quick&dirty measurement with my bench power supply yielded that the working ones started conducting at a voltage close to ±10V. This indicated that the devices in these motors are most likely bidirectional transient voltage suppressor (TVS) devices with an onset voltage in the 10V range. This suggests that one could probably rebuild these motors with modern through hole type TVS units with the right form factor. Another option is of course to just remove the devices, but that runs the risk that the life time of the brushes in the motor may be reduced due to sparking. It probably is also not great for the motor control circuit in the Beogram, but my earlier experiments yielded that it apparently can survive with a snubber-free motor for a while. Anyway, replacement with new TVS units is a bridge I will try crossing for the next motor that shows up with this issue.









Tuesday, January 10, 2017

Beogram 4002 (5513): DC Motor Restoration

I recently received a DC motor from a Beogram 4002 (5513) for restoration. The deck showed the usual RPM variations and so it was time to infuse the bearings of its motor with fresh oil. I posted a video that demonstrates this process in detail a little while ago.  Here are some impressions from my progress on this motor. This shows the motor as received:
And after disassembly:
The bearings are the two small 'donuts'up front to the right. These bearings are Oilite bearings, i.e. porous brass infused with motor oil. Over time the oil gets drawn out by the rotating shaft and eventually they run dry. In extreme cases, such as this motor, one can hear a loud shrieking noise as the shaft grinds on the dry bearing. This shows the bearings freshly under vacuum:
The bubbles represent escaping air from the empty bearing pores. After about 12-24 hrs the bubbling usually stops
and the motor can be reassembled and tested. This shows my 3D printed tool in action to press the tabs of the mounting ring of the top bearing back into place:
After it was assembled I ran it in one of my Beogram 4002s and measured the RPM performance over time with my BeoloverRPM device (which are available to other enthusiasts - just send me a message via the contact form on the right or send an email). This are the before- and after-restoration curves:
The blue curve is the curve I measured before the repair. I stopped the measurement after a short time since the motor started making loud noises and the RPM fluctuated widely. The red curves is the performance after the repair. This motor appears to be back in business!





Monday, January 9, 2017

Beocord 9000: Reassembly

With the recapping, cleaning and maintenance completed today was the day to put things back together in the Beocord and see where this project is at. I am starting with an empty shell since I removed everything out of the Beocord for the restoration. Although there are a few little tricks to learn and master regarding disassembly of this generation of Bang & Olufsen, the inner workings are easy to access.


































The last boards removed are the first boards put back in.





































I am not doing a full reassembly yet because I still have work to do on the displays. It is nice removing the transformer when moving the Beocord around and positioning it because it makes the unit a lot lighter. Here I have the Beocord reassembled to the point I can test it with a tape.

























Now to the other side to see what happens when I push play.























Oh what a great feeling it is to see the unit come to life and actually play a cassette after all of that work! I verified music was coming out using headphones on the front panel jack. You can see that this display does have missing segments and I will be working on those soon. Tomorrow I will set up and run some tests on this deck to see what it looks like on the spectrum analyzer. I will also see if it records. It's nice to end the day with a good success.