Featured Post

Beolover SyncDrive: DC Platter Motor Replacement for Beogram 4002 and 4004 (Type 551x and 552x)

Late Beogram 4002 and the 4004 (Types 551x and 552x), which have DC platter motors instead of the earlier synchronous AC motors usually suff...

Saturday, January 7, 2017

Beocord 9000: Replacing Capacitors Wrapped Up

It took a little longer than expected but I am done with the capacitor replacement in this Beocord 9000 cassette deck. As expected most of the capacitors did test within spec. However, a few were out of spec and two were completely bad. On the Microcomputer/Display board there was that 220uF capacitor (C56) that was preventing the Beocord from coming on. Later, on the Dolby board I found another 220uF (C7) of the same brand that was also completely failed. So even though it is quite a big job it is worth checking out all of the electrolytic capacitors.

Here is a picture of the recap work on the Calibration Oscillator Detector board. Just three 1uF capacitors and I replaced them with WIMA MKS type capacitors.





































Next is the Microcomputer & Display board. There are not many capacitors here and I will be returning to this board to work on the displays.










































































Finally, the board with the most capacitors, the Dolby board.


























I will clean the slider and Dolby switches with Deoxit while I have this board removed.





















Before starting work on the displays I need to check if the Beocord is functioning after the re-capping and re-soldering job. If not, I will have some trouble-shooting to do. So the next step is the re-assembly of the Beocord where I can test it again.

Thursday, January 5, 2017

Beocord 9000: Replacing Capacitors

 Now that it is 2017 and the parties are over it is time to get back to the Beocord 9000 restoration. I started the work replacing the electrolytic capacitors. As I mentioned before, on these Beocord 9000 units it is often the case where very little if any recapping is necessary. This unit appears to have been in storage for quite a while and I already found one bad capacitor so I decided to replace the others.

I typically replace capacitors using audio grade capacitors in the signal path and high reliability, 105°C rated, long lasting capacitors everywhere else. In cases where the capacitor is not in the signal path and is 1uF to 4.7uF, I will often replace the electrolyic capacitor with a WIMA polyester capacitor (MKS). For this recap I removed the Beocord circuit boards so I could inspect and clean them better. I want to examine all of the board connectors closely and reflow the solder joints on them.
The first board is the power supply board.































The next board was the rectifier board.





































After that as the Analog/Digital Converter board



Followed by the Record/Playback board.





























There were three 10uF electrolytic capacitors on the Record/Playback board that I decided to keep. They measured exactly 10uF and had a lower ESR than new replacements that I had in stock.

Since I am also cleaning the Beocord up as I go I removed the Mic. Amplifier board so I could clean the switch and the plugs while I recapped the small board.





































On most of these Beocord units I find a green, sticky substance on the shield wire of audio cables at the connectors. This picture is of a cable with that problem connected to the Mic Amplifier board. I cleaned off the goop and re-soldered the shield wire.





































Here is the Mic Amplifier board all cleaned up and ready for re-installation.





































I should have the remaining Beocord boards recapped tomorrow.

Tuesday, January 3, 2017

Beogram 4000: Replacement of the Reservoir and Motor Capacitors

After rebuilding the carriage transport and arm lowering mechanisms it was time to look into the electrolytic capacitors of the Beogram 4000 that I am currently restoring. I always enjoy replacing the original reservoir and motor capacitors in AC motor Beograms, and the 4000 has quite an impressive array of large cans under the hood:
The first step was to remove the old capacitors:
A quick test with my BK LCR tester revealed two bad capacitors:
One of the 2200uF capacitors was completely gone (7.3 nF), while the other one had a reading of 1300 uF, also out of spec. The others still had some life in them, but of course they also had to go to make sure that this unit will run for a bunch of years without capacitor troubles:
The new modern 105C capacitors that I installed are held in place with a 3D printed assembly that neatly clamps under the original mounting strip that held the old capacitors together. Like all my B&O parts, the capacitor assembly is available to other enthusiasts. Just send me an email or use the contact form on the right. A more detailed post about this procedure with a wiring diagram can be found here.




Thursday, December 29, 2016

Beocord 9000: Pulse Found...Beocord has life

Continuing on with the Beocord power checks today (yesterday actually now)...I moved on to the Beocord regulator board and power supply board.

The regulator board has the +5 VDC and ±15 VDC regulators. They are all mounted on the big heatsink in the back of the Beocord. I like to check the condition of the heatsink compound and the mica insulators to make sure things are not dried out. This Beocord looks pretty good.

























I have seen other cases where the Beocord regulator board had deterioration of the mica insulators and dried out heatsink compound.




















No problems with the regulator board so I moved to the power supply board to check the voltages there. After verifying the ±15 VDC on the board I discovered a 6.5 VDC line from the power supply board to the microcomputer/display board was missing. This measurement point (D15 cathode to ground) should have around +6.2 VDC when the Beocord is turned on (not in standby). Instead, I only measured 15mVDC.


























































I verified the problem wasn't with the regulator and power supply boards. The problem was coming from the destination. It was time to remove the front glass and control panel to look at what is going on. The schematic shows the 6.2 V from the power supply going to capacitor C56 on the microcomputer/display board. Being an electrolytic capacitor it is a suspect so I pulled it and it did indeed measure faulty.






























This was actually good news. Electrolytic capacitors going bad are a common fault in old audio equipment. That is why recapping them is a pretty standard step on most restorations. In these Beocords however, the electrolytic capacitors are known to last a lot longer so they are not always recapped. I was wondering if a recap was in order for this Beocord and now I have my answer. I replaced the C56 capacitor with a new Nichicon 105°C capacitor and the Beocord came to life.























Play, Fast Forward and Reverse all work smoothly with this unit now. This is a good milestone to reach on the restoration.

As can be seen in the picture, the display is missing some segments. It should be displaying 06:25. That problem is also expected and the restoration will be to replace all of the original display LEDs with new SMD (surface mount) LEDs. I will also replace the other Beocord light bulbs with LED replacement assemblies used before on the Beolover Blog.

At this point in the restoration I haven't been able to check the Beocord audio output or record functionality. I will attempt to play the Beocord through an amplifier and measurement equipment tomorrow to see what the "before" scenario is like before doing the capacitor replacement.

Beogram 4000: Restoration of the Arm Lowering Mechanism, Replacement of Tracking Sensor Light Bulb with a LED Assembly, and a New Aluminum Pulley

I started working on the Beogram 4000 that recently arrived with a bit of shipping damage. The first order of business was to reconnect the ejected carriage to its linear rod bearings. This shows the carriage turned over:
and this shows the slide rod with the linear bearings that were liberated from the carriage assembly:
I removed the rod to get the bearings out. This shows them from the bottom:
They have a directionality that needs to be kept in mind when pressing them back into the carriage body. I did that with a big adjustable wrench:
After this procedure I was able to reinstall the carriage and start my normal restoration routine, which usually begins with the rebuilding of the arm lowering mechanism. This shows the solenoid and damper assembly with the connecting linkages and springs:
I removed everything
And spread the parts out:
After cleaning and lubricating I re-assembled the assembly and moved on to the next step, which is the restoration of the linkage between damper and tonearm. This linkage is often stuck or moves only reluctantly. This shows the arms from the back:
Two screws hold the sensor arm in place. After their removal the arm can be taken out:
I removed the linkage. As expected it moved with a lot of resistance and it was difficult to remove it from the pin:
After cleaning the pin and putting some fresh synthetic grease on it, I reassembled everything and adjusted the arm parallelism:
All good again in the arm lowering department. On to the tracking sensor light source. I usually replace the original light bulb setup with my 3D printed LED assembly to ensure long term stability. This shows the original setup:
I removed the bulb housing. This revealed the aperture that sits underneath and controls the light that falls on the light sensors below:
As expected the aperture was pushed to the left due to the shipping issues that reoriented the arms to the right. This will be rectified when I adjust the tracking sensor response. I installed one of my LED assemblies:
The final step was to install a new pulley. I use machined aluminum pulleys provided by Nick (I will be happy to get you in touch if you need one - just use the contact form to the right). This shows the new pulley installed:
Beolovely, I'd say! On to restoring the contacts that control the carriage movements, but that is the topic of the next post about this lovely Beogram.

Tuesday, December 27, 2016

Beocord 9000: Power Supply

 Moving on to the Beocord electrical problems I started with the power supply.  The power supply in this unit was having problems. I wasn't measuring +24 VDC on capacitor C1.  At first I suspected the rectifier board so I pulled it and examined the supply capacitors (C1, C2 and C3).  Here is the rectifier board in the Beocord 9000.





























Here are the C1 through C3 measurements.





































I decided to swap some parts with other Beocord 9000 units I have on hand. This Beocord's rectifier board worked fine in another, working Beocord unit I have so the board is fine. That led me to the transformer. Sure enough, the transformer was the problem.
At first I thought the transformer was defective so I started checking other Beocord 9000 units I have...both working and non-working. I found another one with a non-working transformer and compared the Beocord serial number to the one I am working on. What a surprise! I had another Beocord 9000 unit that was an assembly line mate to the current Beocord I am working on. What are the odds of that? After all of these years these two meet up on the same workbench.





































The transformer turned out to be a non-issue as I remembered the transformer assemblies have an internal 250V, 0.5mA fuse inside. I opened up both transformers and sure enough, the fuses had blown.


































This resolved the Beocord 9000 power supply questions. Now it is on to figure out why the unit will not come on.

Sunday, December 25, 2016

Beocord 9000: Finishing Up The Tape Transport

The Beocord 9000 tape transport repairs have been identified and fixed. I did some more cleaning and lubricated moving parts as I started the reassembly of the tape transport. Even though I don't plan on changing out the Beocord thrust roller, I disassemble that assembly as well to clean and lubricate the parts involved. Here is a picture of that step.





































Here is the tape transport ready for reassembly.

























The first item to go back in is the take-up reel and supply reel assembly. That is followed by the clutch assembly and the interconnecting mechanics.






















After that is the flywheel and belts.


























Finally, the cassette holder and the opening damper assembly.























Since the Beocord 9000 being restored isn't ready for any electrical testing, I pulled an older Beocord 9000 I have and swapped its tape transport with this newly restored transport. I inserted an old pre-recorded cassette (from 1972!) that I always seem to use as a tape transport functional test. It is amazing that it has lived this long without getting eaten.

For this first tape transport test I only tested Play, Fast Forward and Rewind functionality. What I am looking for here is that the Beocord tape transport motor, wheels and belts operate smoothly and don't stop unexpectedly.

One thing to note at this point - I see a lot of Beocord units of the 8000 to 9000 series where people advertise them as just needing new belts. While that is most certainly true, the replacement of the rubber wheels are just as important if the deck is to perform Fast Forward and Rewind functionality reliably. In my first Beocord repair of this type I did everything except the wheels and sure enough, the Fast Forward function was very unsatisfactory. Sometimes it worked sometimes it didn't. The reason was the worn rubber wheels.

The initial tape transport test was a beautiful success. I ran the tape forward all the way to one end, then did a full reverse rewind. After that I spot checked the tape play. Everything worked extremely smooth.
























The next step in the restoration will be to examine the electrical problem with this Beocord.