Here is a quick update on the Beogram 8002 restoration project from Michigan.
I left off with the Forward and Reverse scanning control not able to adjust to the values specified in the service manual.
To fix that I knew I would have to replace the two LDR devices and/or the light source.
It turned out that the two LDR devices measured pretty close to each other when testing them after I removed them. The problem appeared to be with the light source.
I removed the original incandescent lamp and installed an 5mm LED with a 3300 ohm current limiting resistor.
I also tested a couple of new LDR replacements but none of them were as good as the two original devices.
I tested the basic Beogram 8002 Play, Stop, Forward, Reverse operations with this updated control panel and it performed just as I expect it to.
Looking at those on an oscilloscope will show how healthy those signals are.
The results of those tests will be in the next post.