Featured Post

Beolover SyncDrive: DC Platter Motor Replacement for Beogram 4002 and 4004 (Type 551x and 552x)

Late Beogram 4002 and the 4004 (Types 551x and 552x), which have DC platter motors instead of the earlier synchronous AC motors usually suff...

Showing posts with label filter. Show all posts
Showing posts with label filter. Show all posts

Tuesday, March 3, 2015

Beomaster 8000: Recapping the Filter and Tone Control Board

The last Beomaster 8000 PCB that needed its electrolytic capacitors replaced was the Filter and Tone control board that sits underneath the control panel of the unit. After unsoldering the signal strength meter leads, I removed the board from the control panel. Here are is a photo of the board in its original condition:


And after replacing the capacitors with new 105C types:

And a detail shot (the two AD13 ICs are the 64dB volume attenuators for the right and left channels):

Time to put the Beomaster back together and test the 3D printed control panel latch!


Wednesday, January 7, 2015

Beomaster 8000: The Recap Continues

I continued recapping the Beomaster 8000 that sits on my bench right now. I rebuilt the filter and tone control PCB that sits underneath the control panel, the two tuner PCBs, and the preamplifier board. As usual, I used quality Japanese 105C capacitors. I also cleaned all board connectors with a fiberglass brush to remove oxides, and then I coated them with DeoxIT D100L to protect them from future decay. Here are some pictures of the boards before and after:

Filter and tone control PCB before:

and after:

Tuner boards before:
and after:
and a detail shot:


And the preamplifier board before:
and after:
and a detail shot:
On to the main reservoir caps for the outputs! 













Wednesday, August 6, 2014

Beomaster 8000: Recapping the Filter and Tone Controls Board (#4) and Broken Signal Meter

I moved on to recap the filter and tone controls board (PCB #4) that is under the control panel of the Beomaster 8000 I am working on...not much to report about the capacitor replacement. Here are pics:

Before:

and after:




























Sadly, the more 'interesting' part of this board is the non-working signal strength meter. I unsoldered the contacts and measured the resistance. It is open circuit, i.e something is wrong on the inside. It looks pristine inside, from what I can tell by peeking through the plexiglass cover. I am wondering if one can open it up without penalty...I guess, we will find out soon.

Friday, June 20, 2014

Beomaster 8000: PCB 1 and 2 (Tuner) Recapping

Today was Tuner Day of the current Beomaster 8000 restoration project. The tuner worked basically fine, but there was an intermittency on the right channel, seemingly depending on the moon phase...;-). Tracing the signal with the oscilloscope, revealed immediately that one of the contacts in plug P6 was poor. I pulled the boards apart (they come out together...), and cleaned the contacts with a fiberglass pen and bent them a bit for added contact pressure. Then I added a coat of DeoxIT D100. As usual, this seemed to do the trick. Wiggling the boards did not cause problems in the right channel anymore! Here is a pic of the contacts before cleaning...some black oxide spots are clearly visible where the female headers made contact:






































Such black spots come easily off when using a fiberglass pen on them. I forgot to take a picture, but one can achieve as-new looks that way. The DeoxIT further cleans the contacts and provides a protective layer against future oxidation.

While the boards were out, I also recapped them with quality 105C caps. An uneventful procedure. Here is a picture of the boards before the procedure:





























And after:





























And a detail shot of the region around the IF stage (CA3189E):






























Well, almost done!! On to the preamp board (PCB #3)...

Tuesday, June 17, 2014

Beomaster 8000: Rebuilding the Filter and Tone Controls Board (PCB #4)

Today I took the filter and tone controls PCB of the Beomaster 8000 out and replaced the capacitors. This required unsoldering the signal strength meter leads from the PCB, and unscrewing the plastic panel that holds the switches, buttons and sliders. Here is a pic from the bottom of the PCB before taking it out:





























The meter in the lower left corner needs to be unsoldered to be able to remove the PCB from the plastic cover. Five screws hold the PCB to the plastic cover. It is important that these screws do not get tightened too much when re-installing the board. The plastic standoffs can easily crack.

Here is a photo of the meter after unsoldering the leads:






























This is a pic of the board after removing it before replacing the capacitors:





























And with new caps:





























Several of them needed to be tilted to accommodate for the low clearance between the plastic cover and the board. This PCB also had one cracked ceramic capacitor (C207).







I replaced it with a new 10nF type:



After screwing the plastic cover back on (it is a bit difficult to get all the buttons and sliders slotted at the same time - patience helps...;-) I soldered the meter leads back onto the board, and tested the Beomaster...seems all works fine. On to the tuner boards.