Featured Post

Beolover SyncDrive: DC Platter Motor Replacement for Beogram 4002 and 4004 (Type 551x and 552x)

Late Beogram 4002 and the 4004 (Types 551x and 552x), which have DC platter motors instead of the earlier synchronous AC motors usually suff...

Showing posts with label reassembling. Show all posts
Showing posts with label reassembling. Show all posts

Sunday, June 13, 2021

Beogram CD50 From North Carolina: Power Supply Checks and Beosystem 5000 Test

The Beogram CD50 project is ready to wrap up.
I am waiting on some new rubber cabinet feet from Beoparts and those are on the way.
In the meantime I finished the internal CD50 testing by measuring the power supply voltages (+15V, -15V, +5V and -5V).




































































I checked the inside of the CD50 to see if it happened to have the stand-alone IR receiver for the remote control Bang & Olufsen offered as an option.  It is rare to find one with the IR receiver but I have the remote control so I always check.

This CD50 was the typical case and does not have the stand-alone IR receiver.
All of the remote control functionality occurs via cable between the CD50 and a Beomaster 5000.



























...inside the CD50, an empty area where the optional IR receiver goes.



























My final bit of testing then is to connect the CD50 to a Beomaster 5000 and operate it through the Beosystem 5000 remote control unit.






































Everything is working correctly with this CD50.
I will continue some additional listening tests (as that is the best part about these restorations) until the new cabinet feet from Beoparts arrive.
After that this unit will be ready to ship home.

Wednesday, June 9, 2021

Beogram CD50 From North Carolina: Checking capacitors and re-assembly

 I left off the Beogram CD50 project having disassembled the unit to clean off old belt residue and replace the belt (for the CD tray mechanism).

While I had the CD50 disassembled I took a little time to examine the internal electronics and decide if I needed to replace any electrolytic capacitors. The usual case for vintage amplifier and turntable restorations is to replace all of the old electrolytic capacitors due to many (or most, in a lot of cases) being well out of tolerance at this point of their life.  The CD50 is now getting on thirty years old so the capacitors were a concern to me.

In checking with other CD50 restorers I found out that the electrolytic capacitors in the CD50 are usually still good so a complete replacement is not necessary.  Having never checked or replaced the capacitors in a Beogram CD50 I decided I would investigate myself. 

My plan was to go through and pull capacitors, measure them and replace them if necessary.

The capacitors I examined are the ones on the three main circuit boards.
PCB 1 (Display and Key Control), PCB 7 (Servo) and PCB 8 (Decoder & Power Supply).
I am not going to disassemble the front assembly of the CD50 for any of the display boards there. 

Here is a look at the three boards that have the capacitors I am going to look at.
This is how the components were oriented when the CD50 cabinet was first opened up.














The work on the CD tray mechanism required quite a bit of disassembly to where I now have full access to the circuit boards I want to examine the capacitors on.

















Starting with PCB 1...
Note: I removed the metal shield box from the processor IC to reveal the two electrolytic capacitors underneath.


















Starting with the the 1C1 100uF, 25V electrolytic capacitor I guess it was just good luck to try one that is out of tolerance right off the bat.
















Definitely one to replace.
Right below it is the 1C28 safety capacitor. It isn't an electrolytic type capacitor but these capacitors are known to bust open when they fail and there are a few small crack lines in the device. It is better to go ahead and replace these now rather than wait for them to explode :-).



























Here are the replacement capacitors installed.



























The other three electrolytic capacitors on this board were two 10uF, 16V capacitors and another 100uF capacitor.
The 100uF was still in tolerance but close to the lower limit so I replaced it.
The two 10uF capacitors measured good but I decided to go ahead and replace them since I had already replaced the other capacitors on this board.




























That was all for PCB 1.

Next up was PCB 8.



























PCB 8 and PCB 7 have a lot of electrolytic capacitors.  I was prepared to replace all of them but it turned out that they were all still in spec. I did end up replacing all of the 100uF capacitors on PCB 8 like I did on PCB 1. The existing ones were in tolerance but a couple were far enough from the center value that I felt my new capacitors would be better to put in. Also, that way I know for certain those won't be a problem in the future. I also changed the 1000uF and 3300uF capacitors.  They also could have been left in place but I liked my replacement measurements better.

The rest of the capacitors on PCB 8 measured pretty much right on the specified value so I left them in.


























The last board I checked was PCB 7.
That board turned out to just be a capacitor value check only. All of the electrolytic capacitors measured really good.



















The next step is reassembly.
I took a lot of photos of the boards and their cabling when I was disassembling the CD50. That is something you should always do even if you know where all the parts go. You never know when you will want to go back and check exactly how things were connected before you started.

Here are the PCB 1, PCB 7 and PCB 8 boards connected back up.


























I plugged the CD50 in and the CD tray mechanism now works.
After that I loaded a CD and connected the CD50 DIN cable up to the workshop Beomaster 8000 that I keep open (and fully functional) on my workbench.



























































































I let the CD50 play the entire CD.  It properly returned to standby mode after it was done.
It's always a great feeling to see a component perform correctly after a big reassembly task.

The next step is to check some voltages in the CD50 before moving it to a listening room and connecting it up to my Beomaster 5000.  Then I can make sure all of the remote control functionality works properly.

Sunday, February 11, 2018

Beomaster 6000 (2702) restoration: start of reassembling !

Before starting the reassembling I decided to use a piece of wood to put all the different PCB's, frame's, etc. on. The idea is to test the complete Beomaster while on this wood surface and before mounting it back into the frame. By doing this, you have a bit more space around the different parts that allow checking/fixing before final mounting.

During this "operation" I noted a few things that I wanted to address. The first one was the output stage PCB (#11). This long PCB is placed in a narrow subframe. A very narrow place, packed with wires. The PCB is not really fixed and tends to come out every time you handle it. I wanted a permanent solution to remedy this design flaw.

So I constructed two pieces out of aluminium that were glued on both sides to keep the PCB firmly in place.




 

They can still be bend slightly whenever the PCB needs to be taken out again.

The second issue was that one of the input DIN5 connectors started to show a possible los of one of the wings (like what happend on the speaker connector). It was replaced with a "new" one.



The piece of wood I used was a 70 x 40 cm OSB type. I had a larger piece laying around in my garage and cut it to measure.

The level and pre-amplifier PCB's where mounted on the output subframe as well.



And now with the SQ decoder fitted as well.



I like to use my iPad Pro to take pictures of everything I dis-assemble and then use the pictures when re-assembling. Off course the service manuals do provide you with all the needed information, but pictures are handy. And it wouldn't be the first time that errors are found in manuals....Or changes that where made during production that never made it back to the drawing boards for modifying the schematics !



The large output coupling capacitors that are mounted on the black frame with the speaker, input, antenna connectors needed replacement as well. They are fixed with a metal bridge onto this frame. Whenever possible, I like to use new capacitors (in this case Nichicon,  4700µF, 105C type) with the same diameter as the old one. This allows to use the existing metal bridges. Since modern capacitors are smaller than the old one (for the same value), the added advantage is that, keeping the same diameter, they are shorter. This allows for easier connection.



The bridges are off course cleaned and polished first !


And then fitted onto the frame.


It may not look like a Beomaster 6000 quad yet, but it is all starting to come back together !


But still a long way to go...... Keep following my posts !