Thursday, June 1, 2017

Beogram 8000: Completing the Capacitor Replacement and Checking the Work

Today I finished up the capacitor replacement by changing out the motor capacitor in the transformer box and the 5VDC power regulator capacitors on the chassis.

Here is the motor coil coupling capacitor located in the transformer box and its Beolover 3D printed part replacement.






























Very nice and tidy (and secured).
Next were the capacitors for the chassis mounted 5V regulator.



























Now for a quick test to see where this restoration is at. The first thing to check is the +5V power to the microcomputer. I measured the voltage across the new C28 capacitor in the microcomputer board. This is why I haven't close up that board assembly yet.






















Processor supply power looks good and the Beogram 8000 red standby dot illuminated in the speed display window.

Now to check the platter speeds. When this turntable first arrived I did a quick check to see if there was anything noticeably wrong. I remember that the 45 RPM appeared to work but the Beogram was having problems locking in the 33.33 RPM speed.  After the capacitor rework I wanted to check the speeds again.

Both speeds lock right in when selected now.























Those were good test results after the capacitor replacements.  There are still quite a few tasks remaining though. I need to run through the mechanical adjustments and there are several electrical adjustments/checks to do.

Friday, February 17, 2017

Beomaster 8000: Right Channel Output Board Re-checked

I spent the last few days checking the right channel output board components as well as setting up my test bench to do an isolated test of the board.

With the right channel output board assembly completely removed from the Beomaster chassis I de-soldered the connections from the board to the power transistors. This allowed me to measure them with a transistor tester.





































I won't show all of the measurements but I ended up checking all of the transistors and diodes on the board. Every component measured good in their out of circuit state. That being the case, I went ahead while the board was out to recheck capacitors. Again, everything measured fine.

Satisfied that none of the components had a hard failure I decided it was time to reinstall them.

Here are the heatsink components ready to be reinstalled. I cleaned off all of the old compound.





































After studying the assembly to determine the best way to re-install them I decided I must do it while everything is outside the chassis. It would be really difficult to try and mount the components on the mica insulators and try to get the metal clips in place when there is heatsink compound involved.

The order I decided to go with was to install the middle transistor (IC205) first.





































That wasn't too bad. The center transistor is tightly installed and now anchors the wiring harness so the remaining transistors will be easier.
The next transistor I installed was the top transistor (IC204).





































That was followed by the small TR208 (BD165).





















When I got to the bottom TIP146 (IC206), I realized I would end up having to install it upside down from its original installation in order to easily slide the mounting clip in place. I didn't want to do that
so the bottom transistor (IC204) was a little more difficult to get in than it should have been. The easier way to install these would have been to begin with the bottom transistor (IC204) and work my way up to IC206.

The left side installation (TIP141 transistors) is similar to the right. Here is everything reinstalled and cleaned up.





































Here is a better picture of the reworked heatsink mounted components.







I want to retest this board outside of the Beomaster before re-installing it. By using bench power supplies to power the output board I don't have to worry about the rest of the Beomaster and should be able to find out for sure if the problem is on this board.

I had to wait for the arrival of two new 60 VDC adjustable bench power supplies to do this test as the output board rail voltages are ±55 V.  My existing 30 VDC bench power supply can provide the +15 VDC needed. Fortunately the new supplies arrived this week.

Here is the test setup. I created special test wires with connector plugs to attach the power and grounds to the board.





































The power and grounds are marked on the picture and those lines go to the bench power supplies. The two mini-grabber probes are from the DVM to check the no-load idle current.
Here are the bench supplies after slowly ramping up their ±55 VDC rail voltages. That was followed by ramping up the +15 VDC voltage.















When I got the ±55 V supplies ramped up to their levels and the +15 ramped up to its level, I adjusted the no-load idle current to an initial value of 18mV. That resulted in about 0.11 amp current on each 60V supply which is what the expected value is.  Leaving the output board powered up I left it on for a while and the no-load idle current measurement (TP200 to TP201) crept up to about 22mV and settled there.





































This is good news as it appears this output amplifier assembly is good. I will reinstall it in the Beomaster and re-run the burn-in test to see if the earlier fault appears again. That still concerns me as I haven't found a problem related to that yet. In performing my re-check of the output board components I pretty much re-flowed solder on all of the board.

Here is the right channel output board re-install. It can fit in through the back without having to remove the heatsink harness from the board. That is a relief.
























Wired back up.























The power test reveals there is still a problem but it has more clarity now.





















The Beomaster powers up into the Standby mode as it should. When I press a source function (TP2 in this case) the display shows the selected source at the saved volume level.

A missing key event is happening now. There is no delayed, second relay click for the ±55 V rail supplies to kick in. So the Beomaster is showing On but the output amplifier is not powered.

A few days ago, before I removed and checked the right channel output board, I ran tests where I had removed the rail voltage connections from the Beomaster output boards. When I ran the same power on tests the ±55V rail voltages would usually come on (the second relay would engage). However, occasionally the relay would not engage.

Tomorrow I will have to trouble-shoot the start up circuit in the back and see if there is a problem with the power relay.

Saturday, October 26, 2013

Measurements with a Spectrum Analyzer - What Does the dBm Readout Really Mean?

Last year I was given a broken Beomaster 3000-2, and I recently decided to fix it up. It turned out that the tuner has some problems. So I started learning abut FM stereo transmission and RF in general. At some point I started wondering about doing proper radio frequency (RF) measurements and characterizations etc.... I have access to a spectrum analyzer and after playing with it for a bit I was wondering what the 'mysterious' dBm units mean it uses to display its peaks. Well, a visit to wikipedia told me that this stands for dB relative to a power of 1 mW. Great! So what does this mean? Let's look at the formula:

dBm = 10 log (measured power/ 1 mW)

This formula means that dBm gives us the power of the signal relative to a standard 1 mW signal. Why not 1W?...convention. In fact, there is also dBW, which is power relative to, you guessed it, 1W!

So far so good...but what does it really mean? What confused me was "where is this 'measured power' that is compared to 1mW actually measured"? Let's imagine for a moment that we are a Spectrum Analyzer. Sitting inside our enclosure, we see the world through the connector on the front panel, i.e. the measured power must be measured inside the enclosure! not anywhere in the 'device under test' (DUT) where the analyzer is connected to! This is where the 'input impedance' of the analyzer comes into play. On the input of my analyzer it says '50 Ohm'. What this means is that we can basically think of the entire expensive analyzer as a 50 Ohm resistor connected between the input and ground. In other words, when the analyzer is connected to the DUT, then we actually load the DUT output with a 50 Ohm load.

Now it gets pretty straight forward: The measured power in the analyzer is the power dissipated in the 50 Ohm resistor. In other words, if we know the RMS voltage on the input of the analyzer then we can calculate the power in the resistor, and understand the dBm readout.

To validate this concept, I did a simple experiment: I hooked the 50 Ohm output of my waveform generator directly into the 50 Ohm input of the spectrum analyzer. I also hooked my oscilloscope into the output of the waveform generator via a BNC T-adapter. This is the circuit:


















The 50 Ohm, 1 MOhm resistors and the 15 pF capacitor are the internal impedances of the generator, analyzer and oscilloscope. The oscilloscope also has a capacitive impedance, which is 15 pF.

(BTW: this great little schematic was made with iCircuit for iPad...a fantastic way to spend $10! Very easy to play with circuits to understand electronics concepts. The kicker: It does real time simulation while you play with circuit components - give it a try!)

This circuit basically illustrates that the voltage (amplitude) of the signal from the waveform generator is basically divided in half by the 50/50 voltage divider formed by the output impedance of the generator and the input impedance of the analyzer. How about the 1MOhm/15 pF impedance of the oscilloscope? Surely the 1 MOhm does not factor in much, but how about the capacitor? My experiment runs at 10.7 MHz, i.e. if we calculate the impedance of the capacitor via 1/(2*pi*f*C) we get 992 Ohm for this frequency. This means the cap can (at 10.7 MHz) be viewed as a 992 Ohm resistor in parallel with the 50 Ohm impedance of the analyzer. Calculating the resulting total resistance we get 47.6 Ohm, i.e. a change of about 5%. Not too impressive, but one definitely sees a small change in the dBm reading of the analyzer after hooking up the oscilloscope (it was about 0.2 dBm).

My goal in the experiment was to verify that the analyzer indeed gives me a 0 dBm readout if the power dissipated in the 50 Ohm impedance of the analyzer is 1 mW.

This photo shows the readout of the spectrum analyzer after playing with the waveform generator amplitude to achieve an exact 0.00 dBm peak value of the 10.7 MHz peak.:

























Here is the waveform generator screen:


































This means that a 0.64V amplitude apparently delivers 1 mW (0 dBm) into the analyzer 50 Ohm impedance. If the above circuit holds, we should get half this amplitude (0.32V) at the input of the analyzer. A look at the oscilloscope shows this:



























The Rigol DS 1052 apparently measures amplitude across the entire ±wave form. It shows a value of 699 mV, corresponding to a true signal amplitude of 0.35 V, i.e. a bit more than half of the 0.64V shown on the function generator. The 'bit more' is probably a measurement problem. It cannot be explained by the oscilloscope impedance, which should have reduced the reading a bit. Pretty close, though! Lets calculate the power using the presumed 50% (0.32V) amplitude at the analyzer input:

The corresponding RMS amplitude is 0.32V/sqrt(2)=0.226V. Using P=V^2/R to calculate the power, we get: P=0.058/50 W = 0.00102 W = 1.02 mW. Pretty close! The 'mystery' of the spectrum analyzer readout seems to be solved!

While reading up on spectrum analyzers, I learned that they actually work pretty much like a FM tuner. Like a tuner, they work best at a certain input power level. It appears that actually attenuating the signal with a calibrated BNC attenuation 'pad' to a -20dB level or so may be a good idea to protect the fairly sensitive inputs of these devices as long as one has a strong enough signal. This is a bit like using a 1:10 oscilloscope probe as long as your voltages are not too low....this protects the oscilloscope input from too high voltages. For further reading: There is a great (but also rather long) introduction to spectrum analyzers from Agilent. It is posted here: http://cp.literature.agilent.com/litweb/pdf/5952-0292.pdf