After a couple of weeks of functional testing it is time to pack up this Beomaster 8000 receiver and send it home. I hooked up an FM antenna, a Beocord 9000 and a Beogram 8002 as music sources to the Beomaster. It has been a joy playing the system in my workshop while I clean up to begin work on some new projects.
This Beomaster 8000 unit came to me packed better than any I had received before. The owner had it packed in a custom kübox and filled with special foam padding that was molded to the shape of the beomaster.
Packing it back up was just a matter of putting the Beomaster in a plastic bag then onto the bottom foam mold.
The rest of the side and top mold pieces were added and this box is ready to take to the shipping office.
The shipping place will add some banding straps to the kübox and off the package will go.
I am sure the owner will love this Beomaster 8000 again...as I have for the past few weeks :-).
Featured Post
Beolover SyncDrive: DC Platter Motor Replacement for Beogram 4002 and 4004 (Type 551x and 552x)
Late Beogram 4002 and the 4004 (Types 551x and 552x), which have DC platter motors instead of the earlier synchronous AC motors usually suff...
Showing posts with label 2018MJBM8000. Show all posts
Showing posts with label 2018MJBM8000. Show all posts
Wednesday, June 6, 2018
Thursday, May 24, 2018
Beomaster 8000: Wrapping Up The Performance Tests
The current Beomaster 8000 restoration project has been going through quite a bit of testing in the last few weeks. Its owner mentioned that this Beomaster would occasionally come on by itself. Sometimes in the middle of the night it would come out of Standby mode and start playing music. It's always nice to listen to a Beomaster 8000 but you do want it to obey your commands.
I was confident that the restoration work I performed would address that issue but to test it I left the Beomaster plugged in on Standby mode for three full days. No hiccups and it never went into play mode by itself.
It was back to more listening tests while I set up the bench for some performance tests.
As Beolover recently posted, we don't really have the specific test information and test equipment that Bang & Olufsen used when they tested these Beomaster 8000 amplifiers with respect to what is in their technical specifications. On amplifiers there are usually only two service manual adjustments. No-load current (idle current) and DC Offset. That is the case with the Beomaster 8000. Other than those two adjustments a restored amplifier is expected to perform at the manufacturer listed specs for their design. We can use their published specifications as a guide as we collect our own measurements using test equipment available to us today. With these new measurements we will have measurable and repeatable values to compare our amplifier restorations.
Both Beolover and I use the QuantAsylum QA400 Audio Analyzer to make measurements. We also both use 8Ω fixed loads (power resistors mounted to large heatsinks) as dummy speaker loads during the tests. A small 0.08Ω to 0.1Ω resistor is added in series on each speaker load to allow direct measurements to the QA400 analyzer. That is because the full voltage across the 8Ω load would damage the analyzer inputs. I have a pair of QuantAsylum QA190 low noise, differential probes that allow measuring directly across the 8Ω (actually 8.08Ω in my case) dummy load. It should be noted that the updated QuantAsylum QA401 analyzer has built in differential inputs so the external probes are no longer necessary.
Here are some pictures of my test setup.
To run a direct measurement to the QA400 analyzer inputs from the 0.08Ω series resistor I use a coax cable with BNC connections for the analyzer and mini-grabbers for the 0.08Ω resistor.
Here is the Beomaster under test with the QA400 analyzer in the background and its measurement screen on my lab computer.
The QA400 analyzer, as described in Beolover's post, outputs a tone burst test signal for single frequency stimulus tests and a square wave impulse for frequency response test stimulus. I can run both left and right channel measurements at the same time as the analyzer provides the input to the Beomaster Tape 1 or Tape 2 left & right channel source inputs.
This test setup is easy to use and I can connect a bench DMM to the speaker loads to measure the actual voltage put out by the Beomaster output amplifier. One problem I run into is occasional noise that mucks with the measurement device sometimes. Usually down at the line 60Hz frequency. In my test setup the direct measurements across my 0.08Ω series resistor just don't provide as clean a measurement as the QA190 differential probes. I also have to monitor the QA190 probes though as they are battery powered (so the batteries need to be fresh).
For these Beomaster 8000 performance tests I decided to first grab a THD measurement for a 1KHz input signal right before it goes to the Beomaster Output Amplifier board. The audio signal goes from the input source (Tape 1 or 2) through the Preamplifier then to the Filter & Tone Control board. The path from the Filter & Tone Control board to the Output Amplifier is via connector 4P24. For this low voltage test I did use some direct probes with alligator clips to the QA400 inputs and not the QA190 probes. That is because of the space available to connect probes to.
Here is the THD measurement for a 1KHz input signal at 4P24.
The left and right channel THD is very low after going through all of the preamplifier and tone control circuitry. Though it is very low (nearly -100dB) you can see the effect of some 60Hz noise picked up by the measurement cable.
Next was the 1KHz signal THD measurement after the Output Amplifier. This is measured across the 8.08Ω fixed speaker load at different output levels. It should be noted that during these tests I took the opportunity to calibrate the Tape 1 and Tape 2 input level trimmers again so I could make sure they are equal. I also tried to set them where I could set the Beomaster volume control on a level that produces 100W across the 8.08Ω load. The result of that is a Beomaster volume level of 5.4 producing my 100W test output. The next volume level up (5.5) with this setup causes the clipping light to illuminate.
Here are left and right channel THD and SNR measurements at volume levels of 5.4 (~100W) and 5.3 (~67W). I also turned the analyzer A Weighting mode on as the B&O specs use that.
The next volume level up (5.5) on the Beomaster puts the output amplifier into clipping so THD of 0.01% at the rated maximum power into 8.08Ω is very good. The next volume setting down (5.3) drops the THD to 0.008%.
Next is a check of the Beomaster frequency response. Beolover also describes this measurement with the QA400. I am showing the measurement picture produced by the QA400 measurement software (with a few of my own text comments added). It has frequency markers for three points I wanted to focus on (1KHz, 10KHz and 20KHz).
My results are pretty similar to what Beolover got although it appears the QA190 differential probes helped my measurements out on the low frequency noise. The drop at 20KHz was right around 1dB which is more than what the B&O published specs state but then our measurement methods are not exactly the same. Between these Beomaster performance results and the last few we have done it compares with very similar results. The results are definitely a pass for this Beomaster receiver.
I was confident that the restoration work I performed would address that issue but to test it I left the Beomaster plugged in on Standby mode for three full days. No hiccups and it never went into play mode by itself.
It was back to more listening tests while I set up the bench for some performance tests.
As Beolover recently posted, we don't really have the specific test information and test equipment that Bang & Olufsen used when they tested these Beomaster 8000 amplifiers with respect to what is in their technical specifications. On amplifiers there are usually only two service manual adjustments. No-load current (idle current) and DC Offset. That is the case with the Beomaster 8000. Other than those two adjustments a restored amplifier is expected to perform at the manufacturer listed specs for their design. We can use their published specifications as a guide as we collect our own measurements using test equipment available to us today. With these new measurements we will have measurable and repeatable values to compare our amplifier restorations.
Both Beolover and I use the QuantAsylum QA400 Audio Analyzer to make measurements. We also both use 8Ω fixed loads (power resistors mounted to large heatsinks) as dummy speaker loads during the tests. A small 0.08Ω to 0.1Ω resistor is added in series on each speaker load to allow direct measurements to the QA400 analyzer. That is because the full voltage across the 8Ω load would damage the analyzer inputs. I have a pair of QuantAsylum QA190 low noise, differential probes that allow measuring directly across the 8Ω (actually 8.08Ω in my case) dummy load. It should be noted that the updated QuantAsylum QA401 analyzer has built in differential inputs so the external probes are no longer necessary.
Here are some pictures of my test setup.
To run a direct measurement to the QA400 analyzer inputs from the 0.08Ω series resistor I use a coax cable with BNC connections for the analyzer and mini-grabbers for the 0.08Ω resistor.
Here is the Beomaster under test with the QA400 analyzer in the background and its measurement screen on my lab computer.
The QA400 analyzer, as described in Beolover's post, outputs a tone burst test signal for single frequency stimulus tests and a square wave impulse for frequency response test stimulus. I can run both left and right channel measurements at the same time as the analyzer provides the input to the Beomaster Tape 1 or Tape 2 left & right channel source inputs.
This test setup is easy to use and I can connect a bench DMM to the speaker loads to measure the actual voltage put out by the Beomaster output amplifier. One problem I run into is occasional noise that mucks with the measurement device sometimes. Usually down at the line 60Hz frequency. In my test setup the direct measurements across my 0.08Ω series resistor just don't provide as clean a measurement as the QA190 differential probes. I also have to monitor the QA190 probes though as they are battery powered (so the batteries need to be fresh).
For these Beomaster 8000 performance tests I decided to first grab a THD measurement for a 1KHz input signal right before it goes to the Beomaster Output Amplifier board. The audio signal goes from the input source (Tape 1 or 2) through the Preamplifier then to the Filter & Tone Control board. The path from the Filter & Tone Control board to the Output Amplifier is via connector 4P24. For this low voltage test I did use some direct probes with alligator clips to the QA400 inputs and not the QA190 probes. That is because of the space available to connect probes to.
Here is the THD measurement for a 1KHz input signal at 4P24.
The left and right channel THD is very low after going through all of the preamplifier and tone control circuitry. Though it is very low (nearly -100dB) you can see the effect of some 60Hz noise picked up by the measurement cable.
Next was the 1KHz signal THD measurement after the Output Amplifier. This is measured across the 8.08Ω fixed speaker load at different output levels. It should be noted that during these tests I took the opportunity to calibrate the Tape 1 and Tape 2 input level trimmers again so I could make sure they are equal. I also tried to set them where I could set the Beomaster volume control on a level that produces 100W across the 8.08Ω load. The result of that is a Beomaster volume level of 5.4 producing my 100W test output. The next volume level up (5.5) with this setup causes the clipping light to illuminate.
Here are left and right channel THD and SNR measurements at volume levels of 5.4 (~100W) and 5.3 (~67W). I also turned the analyzer A Weighting mode on as the B&O specs use that.
The next volume level up (5.5) on the Beomaster puts the output amplifier into clipping so THD of 0.01% at the rated maximum power into 8.08Ω is very good. The next volume setting down (5.3) drops the THD to 0.008%.
Next is a check of the Beomaster frequency response. Beolover also describes this measurement with the QA400. I am showing the measurement picture produced by the QA400 measurement software (with a few of my own text comments added). It has frequency markers for three points I wanted to focus on (1KHz, 10KHz and 20KHz).
My results are pretty similar to what Beolover got although it appears the QA190 differential probes helped my measurements out on the low frequency noise. The drop at 20KHz was right around 1dB which is more than what the B&O published specs state but then our measurement methods are not exactly the same. Between these Beomaster performance results and the last few we have done it compares with very similar results. The results are definitely a pass for this Beomaster receiver.
Sunday, May 6, 2018
Beomaster 8000: Reassembly for Testing
I can finally start putting this Beomaster back together where it can be put through some functional tests. There is a final component that needs attending to however and that is the door damper for the lid that covers the Filter & Tone Control panel.
The Beomaster 6000, 8000 and Beocord units from this period share a door damper component that keeps a spring loaded lid from flying open. The damper applies some resistance to the spring so the door opening is more controlled.
Here is the damper that came out of this Beomaster 8000 unit. You can see that damping grease has started to leak out. I have seen units where the damping devices are still sealed and don't leak but I have also seen a bunch that are leaking. My guess that the environment they were stored in plays a part in how they have survived.
Here is the damping component opened up.
Ready for the new damping grease.
Here is the reassembled damper installed back in its place in the Beomaster.
It is easiest to reattach the door to the damping component with the Filter & Tone Control board removed. Now that the door is working again I can continue with the rest of the Beomaster reassembly.
During this phase of the project I test play the Beomaster every chance I get. The more actual use of the restored receiver the better. I noticed that the FM tuner didn't sound right and looking at the Signal-Multipath meter in the photo above there should be an illuminated red "MPX" lit up. It is dark in the photo. When the Beomaster 8000 is tuned to an FM stereo station the MPX lamp lights up to indicate it is decoding stereo FM. That is what my ears were trying to tell me. The FM tuner was tuning stations but they were only playing mono.
That means lifting the Filter & Tone Control panel to do a little trouble-shooting of the FM board. Since the problem seemed to involve just the FM stereo functionality I concentrated on the things that just relate to that.
I made some minor adjustments to the 1R45 (Stereo Decoder - oscillator) and 1R41 (Opening of Stereo Decoder) trimmer resistors. Doing that got the MPX LEDs in the Signal-Multipath meter to illuminate on an FM stereo channel. Unfortunately I was still only hearing mono from the Beomaster.
That left the Stereo Decoder chip (1IC3) as the next suspect. It is responsible for decoding the stereo signal. Fortunately I had a spare TCA 4500A chip in stock.
That did the trick. The FM stereo channels now decode properly and the tuner sounds good again.
Here is the fixed FM tuner. The red arrow points out the illuminating MPX light.
Now to finish closing this unit up and begin the final testing.
The Beomaster 6000, 8000 and Beocord units from this period share a door damper component that keeps a spring loaded lid from flying open. The damper applies some resistance to the spring so the door opening is more controlled.
Here is the damper that came out of this Beomaster 8000 unit. You can see that damping grease has started to leak out. I have seen units where the damping devices are still sealed and don't leak but I have also seen a bunch that are leaking. My guess that the environment they were stored in plays a part in how they have survived.
Here is the damping component opened up.
Ready for the new damping grease.
Here is the reassembled damper installed back in its place in the Beomaster.
It is easiest to reattach the door to the damping component with the Filter & Tone Control board removed. Now that the door is working again I can continue with the rest of the Beomaster reassembly.
During this phase of the project I test play the Beomaster every chance I get. The more actual use of the restored receiver the better. I noticed that the FM tuner didn't sound right and looking at the Signal-Multipath meter in the photo above there should be an illuminated red "MPX" lit up. It is dark in the photo. When the Beomaster 8000 is tuned to an FM stereo station the MPX lamp lights up to indicate it is decoding stereo FM. That is what my ears were trying to tell me. The FM tuner was tuning stations but they were only playing mono.
That means lifting the Filter & Tone Control panel to do a little trouble-shooting of the FM board. Since the problem seemed to involve just the FM stereo functionality I concentrated on the things that just relate to that.
I made some minor adjustments to the 1R45 (Stereo Decoder - oscillator) and 1R41 (Opening of Stereo Decoder) trimmer resistors. Doing that got the MPX LEDs in the Signal-Multipath meter to illuminate on an FM stereo channel. Unfortunately I was still only hearing mono from the Beomaster.
That left the Stereo Decoder chip (1IC3) as the next suspect. It is responsible for decoding the stereo signal. Fortunately I had a spare TCA 4500A chip in stock.
That did the trick. The FM stereo channels now decode properly and the tuner sounds good again.
Here is the fixed FM tuner. The red arrow points out the illuminating MPX light.
Now to finish closing this unit up and begin the final testing.
Friday, May 4, 2018
Beomaster 8000: Display Board Back In Business
No problems with the Beomaster 8000 segmented display module burn-in test. All that is needed to complete the display board is to reinstall the display modules and replace the four indicator lamps with Beolover LED replacement boards. The incandescent indicator lamps are for Clipping, Filters, Mono and Manual (as in manual tuning).
The four lamps are outlined in green dotted lines in the following picture. The blue dotted lines show four related resistors (R34, R36, R38 and R40) that are removed when the Beolover LED lamp boards are installed.
Like all of the Beolover replacement parts these lamp modules are direct plug in replacements for the original part. In this case there are the four resistors that get removed but if anyone in the future wanted to return to using incandescent lamps it is a simple matter of soldering in the resistors along with the lamps.
The display board works beautifully again. I tried out all of the modes and all LEDs illuminate as they are supposed to.
This Beomaster is ready to be closed back up and put through some final testing.
The four lamps are outlined in green dotted lines in the following picture. The blue dotted lines show four related resistors (R34, R36, R38 and R40) that are removed when the Beolover LED lamp boards are installed.
Like all of the Beolover replacement parts these lamp modules are direct plug in replacements for the original part. In this case there are the four resistors that get removed but if anyone in the future wanted to return to using incandescent lamps it is a simple matter of soldering in the resistors along with the lamps.
The display board works beautifully again. I tried out all of the modes and all LEDs illuminate as they are supposed to.
This Beomaster is ready to be closed back up and put through some final testing.
Monday, April 30, 2018
Beomaster 8000: Display Board Burn-In Test In Progress
I have been enjoying playing music through this latest Beomaster 8000 unit as I check out the work I have done on it so far. This is always a satisfying and enjoyable time in a project. You feel good about the repair and have a real sense of accomplishment.
Now it is time to get the remaining tasks done and that means shutting off the Beomaster for a while and returning the display board to the bench for the segmented display repairs.
To remove the four LED segmented display modules you have to first desolder their connectors from the board in the back.
Then the plastic holder pieces are removed and the display modules taken out.
You can see more detail of the individual modules on the display reference post I made earlier.
I removed the plastic tabs that hold the display modules together and prepared the boards for new SMD LED replacements.
Here are the four boards after I stripped off the old LEDs. I also cut off the small tab trace I mentioned in the primer so the new SMD devices fit better.
This picture shows an original FM frequency display board next to one that is fully prepared for new LEDs.
Here are the FM frequency and source selection display boards fitted with new SMD LED devices.
This task is the most time consuming and tiring task on the Beomaster 8000 but quite rewarding when you put the restored boards in the test jig and fire the new LEDs up for the first time.
All sixty-five light up perfectly.
I will let these run for twenty-four hours before fully reassembling the modules for installation back onto the display board.
24 Hour Update...
I sealed the display modules up and double-checked that all segments still illuminate.
Now it is time to get the remaining tasks done and that means shutting off the Beomaster for a while and returning the display board to the bench for the segmented display repairs.
To remove the four LED segmented display modules you have to first desolder their connectors from the board in the back.
Then the plastic holder pieces are removed and the display modules taken out.
You can see more detail of the individual modules on the display reference post I made earlier.
I removed the plastic tabs that hold the display modules together and prepared the boards for new SMD LED replacements.
Here are the four boards after I stripped off the old LEDs. I also cut off the small tab trace I mentioned in the primer so the new SMD devices fit better.
This picture shows an original FM frequency display board next to one that is fully prepared for new LEDs.
Here are the FM frequency and source selection display boards fitted with new SMD LED devices.
This task is the most time consuming and tiring task on the Beomaster 8000 but quite rewarding when you put the restored boards in the test jig and fire the new LEDs up for the first time.
All sixty-five light up perfectly.
I will let these run for twenty-four hours before fully reassembling the modules for installation back onto the display board.
24 Hour Update...
I sealed the display modules up and double-checked that all segments still illuminate.
Tuesday, April 24, 2018
Beomaster 8000: Replacing The Microcomputer 2MHz Oscillator Crystals
A while back Beolover encountered a fault where a 2MHz Oscillator Crystal failed in his Beomaster 8000 receiver. Needless to say the Beomaster did not operate properly. You can read about the failure in his previous blog post here.
Since that time we have been replacing these oscillators on our Beomaster 8000 restorations as a preventative measure. The Beomaster 8000 is rather expensive to ship so it is a good idea to guard against faults we have seen before.
As Beolover warns in the original post, you have to take some care and precautions when changing the two oscillator crystals (one for each microcomputer IC). The microcomputer devices can no longer be sourced if a replacement is needed except to raid another Beomaster 8000 unit.
To get started I removed the microcomputer board from the Beomaster again and removed the original oscillator devices.
This picture shows the precaution I use where I short the oscillator pins when the device is desoldered for removal. I also keep the oscillator leads shorted during installation. Shorting the oscillator leads will insure no electrical discharge from the devices cause (fatal) damage to the microcomputer chips.
ADDITIONAL NOTE: Along with shorting the two oscillator device leads together during the removal and installation - the leads should also be connected to the the board ground....which should be connected to the ground of your ESD protective band. Anytime you are handling integrated circuits on these boards you should wear ESD protective bands and properly ground them.
Along with the X1 and X2 oscillator devices capacitors C17, C18, C95 and C97 capacitors must be changed. The capacitor values are determined by the oscillator device. In this case I used the same oscillator that Beolover originally used (21M6819). That oscillator calls for two 18pF capacitors.
Here are the new parts installed on the microcomputer board. I used a little Aleene's Tacky Glue to secure the oscillators to the board.
After re-installing the microcomputer board back in the Beomaster I started up the receiver and I am now listening to the FM tuner again. Another task off the list.
The display board is next on the list.
Since that time we have been replacing these oscillators on our Beomaster 8000 restorations as a preventative measure. The Beomaster 8000 is rather expensive to ship so it is a good idea to guard against faults we have seen before.
As Beolover warns in the original post, you have to take some care and precautions when changing the two oscillator crystals (one for each microcomputer IC). The microcomputer devices can no longer be sourced if a replacement is needed except to raid another Beomaster 8000 unit.
To get started I removed the microcomputer board from the Beomaster again and removed the original oscillator devices.
This picture shows the precaution I use where I short the oscillator pins when the device is desoldered for removal. I also keep the oscillator leads shorted during installation. Shorting the oscillator leads will insure no electrical discharge from the devices cause (fatal) damage to the microcomputer chips.
ADDITIONAL NOTE: Along with shorting the two oscillator device leads together during the removal and installation - the leads should also be connected to the the board ground....which should be connected to the ground of your ESD protective band. Anytime you are handling integrated circuits on these boards you should wear ESD protective bands and properly ground them.
Along with the X1 and X2 oscillator devices capacitors C17, C18, C95 and C97 capacitors must be changed. The capacitor values are determined by the oscillator device. In this case I used the same oscillator that Beolover originally used (21M6819). That oscillator calls for two 18pF capacitors.
Here are the new parts installed on the microcomputer board. I used a little Aleene's Tacky Glue to secure the oscillators to the board.
After re-installing the microcomputer board back in the Beomaster I started up the receiver and I am now listening to the FM tuner again. Another task off the list.
The display board is next on the list.
Subscribe to: