Featured Post

Beolover SyncDrive: DC Platter Motor Replacement for Beogram 4002 and 4004 (Type 551x and 552x)

Late Beogram 4002 and the 4004 (Types 551x and 552x), which have DC platter motors instead of the earlier synchronous AC motors usually suff...

Tuesday, October 8, 2019

Beomaster 2400: Packing up the Beomaster for shipment

The Beomaster 2400 played continuously for about forty-eight hours without any problem. I exercised all of the source inputs and even made a test recording from a Beogram 8002 to a Beocord 9000.

Now it is time to properly pack the unit up and ship it home.

The following pictures show how to pack the Beomaster 2400 for safe shipping.




















It is a good idea to use a plastic bag to protect from any packing material scratching of the audio component and to act as a moisture barrier.



















I like to use 1 1/2 inch eggcrate foam for protecting the Beomaster and secure it with non-adhesive packing wrap).



















For the shipping box I glue the bottom flaps together with wood glue then glue polyethylene padding to the floor and walls of the box.






















I place the wrapped Beomaster into the padded shipping box and use more eggcrate foam for the ends and the middle of the Beomaster .












































Now I can place the polyethylene lid over the packed Beomaster and seal up the box.
























This Beomaster 2400 is ready to go.

Saturday, October 5, 2019

Beomaster 2400: Finishing up with the listening tests

Time to wrap up this Beomaster 2400 restoration project. It is reassembled and all of the testing is done. I have had this receiver in one of my listening test rooms for a while. It has performed great connected up to a Beocord 9000, Beogram 8002 and a pair of Beovox M100.2.  Those speakers are rather large for this slim, little receiver but in a ten foot by eleven foot room it works out fine.

This Beomaster is ready for another forty years of music enjoyment.












A few more hours of listening and I will pack it up and ship it home.

Thursday, October 3, 2019

Beogram 4004: DC Motor Bearings Oil Infusion and Spark Snubber Replacement

A Beogram 4004 DC Motor arrived from Oregon for restoration. A brief bench test revealed the usual shrieking noise coming from dry bearings. This shows the motor as received:
I took the motor apart to remove the bearings:
The bearings are the two small donuts on the black pad. I immersed them in motor oil and pulled a vacuum. Immediately vigorous bubbling started:
This indicated that the air was drawn from the pores of the Oilite bearing material to make room for oil diffusion. After about 3 days the bubbling stopped and the bearings were ready for reinstallation. I put the motor back together and installed it in one of my Beogram 4002s for a RPM stability test with my BeoloverRPM device:
The BeoloverRPM allows logging of the RPM for extended periods of time. The red curve in the graph below shows the curve that I measured:

Far from perfect! The sudden RPM drops indicated that a spark snubber was occasionally shorting out one of the rotor coils. They usually start going bad in this intermittent way. I took the motor apart again to extract the rotor for spark snubber replacement. This shows the rotor with the snubbers up (on the black pad you can see the replacement TVS devices that I had prepared for soldering onto the rotor):

I unsoldered the original snubbers ('ring' on the black pad)
and then installed the TVS units:
I put the motor back together for another RPM test. This second measurement is shown in blue in the above graph. The negative spikes are gone, i.e. this motor is ready for duty again!







Thursday, September 19, 2019

Beogram 4002: DC Platter Motor Restoration

A Beogram 4002 DC platter motor arrived from New York for some TLC. This shows the motor:
I took it apart to get to the bearings for oil infusion:
The bearings are the two small donuts on the black pad. I immersed them in motor oil and pulled a vacuum:
Immediately, the usual bubbling started indicating that air was drawn from the pores of the oil depleted bearing material. As the air is drawn out, oil can diffuse in replenishing the bearing material for another tour of duty.
After about 48 hours the bubbling stopped and I extracted the bearings for reinstallation:
I put the motor back together and installed it in one of my Beogram 4002s for the RPM stability test with my BeoloverRPM device:
The BeoloverRPM can log the RPM in 10s intervals for extended periods of time. This allows pinpointing intermittent RPM issues. This is the curve I measured after 24 hrs:

This result is as good as it gets! This motor is ready for duty again!





Monday, September 16, 2019

Beogram 4002 DC Motor Restoration

A Beogram 4002 DC platter motor recently arrived from Florida for restoration. It emitted the usual shrieking noises when I ran it from my bench supply. A clear indication that the bearings were dry. This shows the motor as received:
I took the motor apart to extract the bearings (on the black pad):
Then it was time to immerse them in motor oil and pull a vacuum:
Immediately, vigorous bubbling started indicative of air being drawn from the pores of the Oilite bearing material to make room for oil. After about 2 days the bubbling stopped after the oil was replenished in the bearing. I extracted the bearings:
And then it was time to reassemble the motor. I installed it in one of my Beogram 4002s and ran a 24 hrs stability test with my BeoloverRPM device:
The BeoloverRPM can log the RPM over extended periods of time. This is the RPM curve I measured for this motor:
This is as good as it gets for 4002 DC platter motors, i.e. this motor is ready for duty again.





Monday, September 9, 2019

Beomaster 2400 Type 2902: Retesting performance measurements after the right channel rework

My break from the workbench is over. Time to resume and wrap up this Beomaster 2400 restoration.

I left off with the discovery that the right channel output amplifier was distorting.

In resuming work on this Beomaster I removed and tested all of the right channel output amplifier transistors out of circuit. It wasn't any surprise that they all tested good since the right channel was working at low power levels. That being the case I decided to replace all of those transistors in the right channel along with the two emitter resistors. I also wasn't happy with the single-turn trimmer resistors I had installed for the no-load current adjustment. The single-turn resistors are fine but I prefer a multi-turn resistor for that particular adjustment. It is easier for me to dial in the correct value and feels more precise.

Here are pictures of the transistors that were replaced and the new trimmers.












































The new multi-turn trimmers made re-adjusting the no-load current adjustment a breeze.

Now it was time for checking the left and right output amplifier channels THD again.
This type of measurement poses a problem regarding my stating that the THD for this amplifier is exactly per the service manual published technical data.

For one thing, the published audio specs stated by various manufacturers are a little vague. They often quote DIN specs that they followed but details of those specifications are difficult to find. Even then, the measurement equipment is different now.

My methodology is to use the manufacturer specs as a guide but measure all of my amplifiers using my own same test setup and same measurement devices. That gives me a set of data I know the source of and can use for comparison.

I have shown this before but here is my test setup.

I use a fixed, dummy speaker load of 8.08Ω on each channel. The 0.08Ω part of the load is a series sense resistor that I can connect my audio analyzer probes to for making power signal measurements with. The audio analyzers have limits on the AC voltage they can handle. While my QuantAsylum QA401 analyzer does have built in attenuators I still need to be careful.






















The test connections go to my signal generator, QA401 analyzer, multimeters, oscilloscope, dummy load restistors and the amplifier under test (BM2400 in this case).

I use the multimeters to verify the AC signal the amplifier is outputting to the load resistors.
The Beomaster 2400 doesn't have a volume control that you can tell the precise volume level you are on. It does have three preset volume levels you can select from on start up though so I usually use those.  Then I use the amplitude adjustment of the test signal generator and check the amplifier output with the multimeter to dial in a precise measurment output. The oscilloscope also aids in monitoring the actual input signal and amplifier output signal.
The QA401 audio analyzer measures the THD.

































































Here is a quick look at the Beomaster 2400 service manual technical data.





















I am only interested in the rated power output and the distortion data.
Bang & Olufsen states here that they used DIN 45 500 for their measurement specification. I don't have those specs and I'm not sure they would really help me with the test equipment I have on hand.

So I will use the technical data that says this amplifier should be able to output 20W into 8Ω speaker loads. It should do that at a THD value close to what the THD is at lower output power.  My dummy loads are fixed resistor loads and that is fine as I use those on all of my tests. Plus I am collecting my own measurement data for apple to apple comparisons.

The service manual stated harmonic distortion spec of 1000Hz, 50mW : <0.07% seems kind of odd.
I am reading that to mean a 1000Hz test sine wave input and the Beomaster output set to only 50mW  across an 8Ω load. That is only about 0.6Vrms.

I decided to go ahead and make that measurement anyway but I still will do my own THD measurement at the full 20W output.

Here is the 50mW THD measurement for the left and right channels of the Beomaster 2400.






















Both channels are in the 0.035% range which is well below 0.07%.
So if that is what the published spec meant then great.

For my own full power test at 20W of amplifier output across the 8Ω loads I get this -






















This is what I wanted to see. The left and right channels are both performing close to each other and at a respectable THD of around 0.04% (at full rated power).
The Beomaster 2400 heatsinks do really warm up at this output level and normal listening level for the amplifier is probably down around 1W to 5W.

One last note about just doing the THD measurements here. Most of the time restorers rely on listening to known, good music sources through known good speakers to check the result of an audio restoration.  That is fine and an important test to pass.  I just feel more comfortable in having a repeatable instrument measurement test as a means to check that there isn't something hidden going on and that both channels measure close to what my other restorations have been. It paid off in this case because this Beomaster sounded fine in my initial listening tests after the recap but the higher power testing revealed a problem.

This amplifier is ready to move on to the final functional tests.
Those are where I will connect up a Beogram and Beocord then play the Beomaster 2400 for several days continuously (most of the time using FM as the source).

Thursday, August 22, 2019

Beogram 4004: Restoration of DC Platter Motor

I recently received a Beogram 4004 DC platter motor from Texas. The motor exhibited the typical shrieking noises when running it from a bench supply at 5V. A clear indication of dry bearings.
This shows the motor as received:
I took the motor apart to get the brass bearings out for oil infusion:
The bearings are the two small donuts on the black pad up front. I immersed them in motor oil and pulled a vacuum. Immediately vigorous bubbling started, indicating thirsty bearings:
After about 48 hours the bubbling stopped (indicating that the bearings were replenished with oil) and I extracted the bearings:
Then I reassembled the motor and installed it in one of my Beogram 4002s for a 24 hrs RPM stability test using the BeoloverRPM device. The BeoloverRPM allows logging the RPM every 10 seconds over extended periods of time. This is the curve I measured:
This result is as good as it gets! This motor is ready for duty again!