Beogram 4002 (5513): A New Exciting DC Motor Failure Mode Due to a Shorted Spark Snubber

Another Beogram 4002 (5513) DC motor arrived recently for some TLC. When I did the usual pre-restoration test in one of my Beogram 4002s, this motor only ran very sluggishly and only if I would help it along a bit. This made it stand out from the usual DC motor that I am seeing on my bench. Usually, these motors run vigorously, but they have strong RPM variations and often make shrieking noises due to dry Oilite bearings. This one was very lackluster and weak in comparison.
I opened it up and did my usual oil infusion of the bearings to make sure that the mechanical aspects were up to spec before I would look into the sluggishness issue. Here are a few impressions of the Oilite bearing oil-re-infusion process. This shows the motor as received:

And disassembled:
This are the bearings in motor oil under vacuum:
The bubbles rising from the smaller (bottom) bearing is air being released from the porous Ni "Oilite" material while it is being replenished with oil. The top bearing only released a few bubbles indicating that it still had oil in it.
After 24 hrs the bubbling stopped and I reassembled the motor. When I tested it the sluggishness had not changed, i.e. there was definitely another issue beyond dry bearings.

I opened the motor up again and I remembered that I had a similar issue a while back. In that case I was able to get the motor running again after removing the spark snubbers that are connected across the three coils on the rotor. Spark snubbers short circuit the EMF that is generated due to Faraday's law when the commutator switches between coils. This prevents sparks and potential damage to the driver circuitry. This shows the rotor hooked up to a multimeter in resistance measuring mode:
The three blue units arranged on a ring around the commutator are the snubbers. Normally, they are insulating at the low voltages typically applied during a resistance measurement. The 16.8 Ohm that show up here is the resistance of the rotor coil this particular snubber is connected in parallel. I measured the snubber one over:
22.9 Ohm for the next coil. On to the third snubber:
This measurement shows that it has a short. This effectively takes the associated coil out of business and this explains why this motor did not have any power. It only ran on two cylinders instead of three, so to speak. From the previous motor with this issue I still had the three-spark-snubber assembly in my B&O parts box. This shows it in front of the rotor:
I cut out (they are spot welded together) the shorted snubber from the rotor and implanted one of the still working ones of the extracted assembly:
A test with the multimeter showed that this coil now had again about 20 Ohms.
I reassembled the motor for the second time, and inserted it into the Beogram 4002. I hooked up my BeoloverRPM device (which is available to other enthusiasts - just send me an email or use the contact form to the right) and did a 12 hrs run. This is the curve I measured:
It appears this motor is up to spec again.

I read up a bit about spark-snubbers in motors. There are many different types of these devices. A quick&dirty measurement with my bench power supply yielded that the working ones started conducting at a voltage close to ±10V. This indicated that the devices in these motors are most likely bidirectional transient voltage suppressor (TVS) devices with an onset voltage in the 10V range. This suggests that one could probably rebuild these motors with modern through hole type TVS units with the right form factor. Another option is of course to just remove the devices, but that runs the risk that the life time of the brushes in the motor may be reduced due to sparking. It probably is also not great for the motor control circuit in the Beogram, but my earlier experiments yielded that it apparently can survive with a snubber-free motor for a while. Anyway, replacement with new TVS units is a bridge I will try crossing for the next motor that shows up with this issue.









Tuesday, January 10, 2017

Beogram 4002 (5513): DC Motor Restoration

I recently received a DC motor from a Beogram 4002 (5513) for restoration. The deck showed the usual RPM variations and so it was time to infuse the bearings of its motor with fresh oil. I posted a video that demonstrates this process in detail a little while ago.  Here are some impressions from my progress on this motor. This shows the motor as received:
And after disassembly:
The bearings are the two small 'donuts'up front to the right. These bearings are Oilite bearings, i.e. porous brass infused with motor oil. Over time the oil gets drawn out by the rotating shaft and eventually they run dry. In extreme cases, such as this motor, one can hear a loud shrieking noise as the shaft grinds on the dry bearing. This shows the bearings freshly under vacuum:
The bubbles represent escaping air from the empty bearing pores. After about 12-24 hrs the bubbling usually stops
and the motor can be reassembled and tested. This shows my 3D printed tool in action to press the tabs of the mounting ring of the top bearing back into place:
After it was assembled I ran it in one of my Beogram 4002s and measured the RPM performance over time with my BeoloverRPM device (which are available to other enthusiasts - just send me a message via the contact form on the right or send an email). This are the before- and after-restoration curves:
The blue curve is the curve I measured before the repair. I stopped the measurement after a short time since the motor started making loud noises and the RPM fluctuated widely. The red curves is the performance after the repair. This motor appears to be back in business!





Monday, January 9, 2017

Beocord 9000: Reassembly

With the recapping, cleaning and maintenance completed today was the day to put things back together in the Beocord and see where this project is at. I am starting with an empty shell since I removed everything out of the Beocord for the restoration. Although there are a few little tricks to learn and master regarding disassembly of this generation of Bang & Olufsen, the inner workings are easy to access.


































The last boards removed are the first boards put back in.





































I am not doing a full reassembly yet because I still have work to do on the displays. It is nice removing the transformer when moving the Beocord around and positioning it because it makes the unit a lot lighter. Here I have the Beocord reassembled to the point I can test it with a tape.

























Now to the other side to see what happens when I push play.























Oh what a great feeling it is to see the unit come to life and actually play a cassette after all of that work! I verified music was coming out using headphones on the front panel jack. You can see that this display does have missing segments and I will be working on those soon. Tomorrow I will set up and run some tests on this deck to see what it looks like on the spectrum analyzer. I will also see if it records. It's nice to end the day with a good success.

Saturday, January 7, 2017

Beocord 9000: Replacing Capacitors Wrapped Up

It took a little longer than expected but I am done with the capacitor replacement in this Beocord 9000 cassette deck. As expected most of the capacitors did test within spec. However, a few were out of spec and two were completely bad. On the Microcomputer/Display board there was that 220uF capacitor (C56) that was preventing the Beocord from coming on. Later, on the Dolby board I found another 220uF (C7) of the same brand that was also completely failed. So even though it is quite a big job it is worth checking out all of the electrolytic capacitors.

Here is a picture of the recap work on the Calibration Oscillator Detector board. Just three 1uF capacitors and I replaced them with WIMA MKS type capacitors.





































Next is the Microcomputer & Display board. There are not many capacitors here and I will be returning to this board to work on the displays.










































































Finally, the board with the most capacitors, the Dolby board.


























I will clean the slider and Dolby switches with Deoxit while I have this board removed.





















Before starting work on the displays I need to check if the Beocord is functioning after the re-capping and re-soldering job. If not, I will have some trouble-shooting to do. So the next step is the re-assembly of the Beocord where I can test it again.

Thursday, January 5, 2017

Beocord 9000: Replacing Capacitors

 Now that it is 2017 and the parties are over it is time to get back to the Beocord 9000 restoration. I started the work replacing the electrolytic capacitors. As I mentioned before, on these Beocord 9000 units it is often the case where very little if any recapping is necessary. This unit appears to have been in storage for quite a while and I already found one bad capacitor so I decided to replace the others.

I typically replace capacitors using audio grade capacitors in the signal path and high reliability, 105°C rated, long lasting capacitors everywhere else. In cases where the capacitor is not in the signal path and is 1uF to 4.7uF, I will often replace the electrolyic capacitor with a WIMA polyester capacitor (MKS). For this recap I removed the Beocord circuit boards so I could inspect and clean them better. I want to examine all of the board connectors closely and reflow the solder joints on them.
The first board is the power supply board.































The next board was the rectifier board.





































After that as the Analog/Digital Converter board



Followed by the Record/Playback board.





























There were three 10uF electrolytic capacitors on the Record/Playback board that I decided to keep. They measured exactly 10uF and had a lower ESR than new replacements that I had in stock.

Since I am also cleaning the Beocord up as I go I removed the Mic. Amplifier board so I could clean the switch and the plugs while I recapped the small board.





































On most of these Beocord units I find a green, sticky substance on the shield wire of audio cables at the connectors. This picture is of a cable with that problem connected to the Mic Amplifier board. I cleaned off the goop and re-soldered the shield wire.





































Here is the Mic Amplifier board all cleaned up and ready for re-installation.





































I should have the remaining Beocord boards recapped tomorrow.

Tuesday, January 3, 2017

Beogram 4000: Replacement of the Reservoir and Motor Capacitors

After rebuilding the carriage transport and arm lowering mechanisms it was time to look into the electrolytic capacitors of the Beogram 4000 that I am currently restoring. I always enjoy replacing the original reservoir and motor capacitors in AC motor Beograms, and the 4000 has quite an impressive array of large cans under the hood:
The first step was to remove the old capacitors:
A quick test with my BK LCR tester revealed two bad capacitors:
One of the 2200uF capacitors was completely gone (7.3 nF), while the other one had a reading of 1300 uF, also out of spec. The others still had some life in them, but of course they also had to go to make sure that this unit will run for a bunch of years without capacitor troubles:
The new modern 105C capacitors that I installed are held in place with a 3D printed assembly that neatly clamps under the original mounting strip that held the old capacitors together. Like all my B&O parts, the capacitor assembly is available to other enthusiasts. Just send me an email or use the contact form on the right. A more detailed post about this procedure with a wiring diagram can be found here.




Thursday, December 29, 2016

Beocord 9000: Pulse Found...Beocord has life

Continuing on with the Beocord power checks today (yesterday actually now)...I moved on to the Beocord regulator board and power supply board.

The regulator board has the +5 VDC and ±15 VDC regulators. They are all mounted on the big heatsink in the back of the Beocord. I like to check the condition of the heatsink compound and the mica insulators to make sure things are not dried out. This Beocord looks pretty good.

























I have seen other cases where the Beocord regulator board had deterioration of the mica insulators and dried out heatsink compound.




















No problems with the regulator board so I moved to the power supply board to check the voltages there. After verifying the ±15 VDC on the board I discovered a 6.5 VDC line from the power supply board to the microcomputer/display board was missing. This measurement point (D15 cathode to ground) should have around +6.2 VDC when the Beocord is turned on (not in standby). Instead, I only measured 15mVDC.


























































I verified the problem wasn't with the regulator and power supply boards. The problem was coming from the destination. It was time to remove the front glass and control panel to look at what is going on. The schematic shows the 6.2 V from the power supply going to capacitor C56 on the microcomputer/display board. Being an electrolytic capacitor it is a suspect so I pulled it and it did indeed measure faulty.






























This was actually good news. Electrolytic capacitors going bad are a common fault in old audio equipment. That is why recapping them is a pretty standard step on most restorations. In these Beocords however, the electrolytic capacitors are known to last a lot longer so they are not always recapped. I was wondering if a recap was in order for this Beocord and now I have my answer. I replaced the C56 capacitor with a new Nichicon 105°C capacitor and the Beocord came to life.























Play, Fast Forward and Reverse all work smoothly with this unit now. This is a good milestone to reach on the restoration.

As can be seen in the picture, the display is missing some segments. It should be displaying 06:25. That problem is also expected and the restoration will be to replace all of the original display LEDs with new SMD (surface mount) LEDs. I will also replace the other Beocord light bulbs with LED replacement assemblies used before on the Beolover Blog.

At this point in the restoration I haven't been able to check the Beocord audio output or record functionality. I will attempt to play the Beocord through an amplifier and measurement equipment tomorrow to see what the "before" scenario is like before doing the capacitor replacement.